电话:
400-7060-959
传真:
+86 10 56315212-8813
电子邮件:
orders@antibodies-online.cn

IL-1 beta ELISA 试剂盒

IL1B 适用: 大鼠 Colorimetric Sandwich ELISA 15.6-1000 pg/mL
产品编号 ABIN955896
发货至: 中国
  • 抗原 See all IL-1 beta (IL1B) ELISA试剂盒
    IL-1 beta (IL1B) (Interleukin 1, beta (IL1B))
    适用
    • 14
    • 11
    • 7
    • 6
    • 5
    • 5
    • 4
    • 4
    • 3
    • 3
    • 3
    • 2
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    大鼠
    检测方法
    Colorimetric
    实验类型
    Sandwich ELISA
    检测范围
    15.6-1000 pg/mL
    最低检测浓度
    15.6 pg/mL
    应用范围
    ELISA
    原理
    This ELISA kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of rat IL1B in serum, plasma, tissue homogenates, cell culture supernates, and other biological fluids.
    Analytical Method
    Quantitative
    特异性
    This assay has high sensitivity and excellent specificity for detection of rat IL1B. No significant cross- reactivity or interference was observed.
    灵敏度
    The minimum detectable dose of rat IL1 B is typically less than 4.2 pg/mL.
    The Sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by the mean O.D. value of 20 replicates of the zero calibrator plus three standard deviations.
    产品特性
    The microtiter plate provided in this kit has been pre-coated with an antibody specific to IL1B. Calibrators and samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for IL1B. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the TMB substrate solution is added to each well. Only those wells that contain IL1B, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulfuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm +/- 2 nm. The concentration of IL1B in the samples is then determined by comparing the O.D. of the samples to the calibration curve.
    组件
    Pre-coated, ready to use 96-well plate (1x)
    Calibrator (lyophilized) (2x)
    Calibrator Diluent (1 x 20 mL)
    Detection Reagent A (1 x 120 µL)
    Detection Reagent B (1 x 120 µL)
    Assay Diluent A (2X concentrate) (1 x 6 mL)
    Assay Diluent B (2X concentrate) (1 x 6 mL)
    TMB Substrate (1 x 9 mL)
    Stop Solution (1 x 6 mL)
    Wash Buffer (30X concentrate) (1 x 20 mL)
    Plate sealer for 96 wells (4x).
    试剂未包括
    1. Microplate reader with 450 +/- 10 nm filter.
    2. Precision single and multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. De-ionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
    Featured
    Discover our best selling IL1B ELISA Kit
    Top Product
    Discover our top product IL1B ELISA Kit
  • 说明

    The calibration curve concentrations used for the ELISA's were 1000, 500, 250, 125, 62.5, 31.2, 15.6 pg/mL.

    板类型
    Pre-coated
    结果分析

    Average the duplicate readings for each calibrator, control, and sample and subtract the average zero calibrator optical density. Create a calibration curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a calibration curve by plotting the mean absorbance for each calibrator on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the IL1B concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. It is recommended to use some related software to do this calculation. If samples have been diluted, the concentration read from the calibration curve must be multiplied by the dilution factor.

    限制
    仅限研究用
  • 储存条件
    -20 °C
    储存方法
    All the reagents should be kept according to the labels on vials. The Calibrator, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20° C upon being received. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable until the expiration date shown, provided it is stored as prescribed above.
    有效期
    The expiry date is stated on the label.
  • 抗原 See all IL-1 beta (IL1B) ELISA试剂盒
    IL-1 beta (IL1B) (Interleukin 1, beta (IL1B))
    别名
    IL1b (IL1B 产品)
    别名
    IL-1 ELISA Kit, IL1-BETA ELISA Kit, IL1F2 ELISA Kit, IL-1BETA ELISA Kit, IL1beta ELISA Kit, il1-b ELISA Kit, zgc:111873 ELISA Kit, IL-1B ELISA Kit, IL-1beta ELISA Kit, Il-1b ELISA Kit, IL1B ELISA Kit, IL-1 beta ELISA Kit, IL-1b ELISA Kit, interleukin 1 beta ELISA Kit, interleukin 1, beta ELISA Kit, IL1B ELISA Kit, il1b ELISA Kit, Il1b ELISA Kit
    途径
    NF-kappaB Signaling, Interferon-gamma Pathway, TLR signaling, Negative Regulation of Hormone Secretion, Cellular Response to Molecule of Bacterial Origin, Carbohydrate Homeostasis, Glycosaminoglycan Metabolic Process, Myometrial Relaxation and Contraction, Regulation of Leukocyte Mediated Immunity, Positive Regulation of Immune Effector Process, Autophagy, Cancer Immune Checkpoints, Inflammasome
You are here:
客服