电话:
400-7060-959
传真:
+86 10 56315212-8813
电子邮件:
orders@antibodies-online.cn

C9 IQ-ELISA 试剂盒

C9 适用: 人 qPCR DNA-Binding ELISA Cell Culture Supernatant, Plasma, Serum
产品编号 ABIN6810522
发货至: 中国
  • 抗原 See all C9 IQ-ELISA Kits
    C9 (Complement Component C9 (C9))
    适用
    • 6
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    检测方法
    qPCR
    实验类型
    DNA-Binding ELISA
    应用范围
    ELISA
    原理
    Human Immunoquantitative (PCR-Based) C9 ELISA Kit for cell culture supernatants, plasma, and serum samples.
    样品类型
    Cell Culture Supernatant, Plasma, Serum
    Analytical Method
    Quantitative
    产品特性
    The Immuno Quantitative Enzyme Linked ImumunoSorbent Assay (IQELISA™) is an innovative new assay that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of lower sample volumes while also providing more sensitivity. The Human C9 IQELISA™ Kit is a modified ELISA assay with high sensitivity qPCR readout for the quantitative measurement of Human C9 in serum, plasma, and cell culture supernatants. This assay employs an antibody specific for Human C9 coated on a 96-well PCR plate. Standards and samples are pipetted into the wells and C9 present in a sample is bound to the wells by the immobilized antibody. The wells are washed and a detection affinity molecule is added to the plates. After washing away unbound detection affinity molecule, primers and a PCR master mix are added to the wells and data is collected using qPCR. Ct values obtained from the qPCR are then used to calculate the amount of antigen contained in each sample, where lower Ct values indicate a higher concentration of antigen.
    组件
    • C9 Microplate (Item A): 96 well PCR plate coated with anti-Human C9
    • Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution
    • Standards (Item C): 2 vials of recombinant Human C9
    • Assay Diluent A (Item D): 30 ml diluent buffer, 0.09% sodium azide as preservative. For Standard/Sample (serum/plasma) diluent
    • Assay Diluent B (Item E): 15 ml of 5x concentrated buffer. For Standard/Sample (cell culture medium/urine) diluent
    • Detection Affinity Reagent for C9 (Item F): 2 vials of a 4x concentrated solution of anti-Human C9 affinity reagent
    • IQELISA Detection Reagent (Item G): 1.4ml of a 10x concentrated stock
    • Primer Solution (Item I): 1.7 ml vial
    • PCR Master Mix (Item J): 1.2 ml vial
    • PCR Preparation buffer (Item K): 1ml vial of 10x concentrated buffer
    • Final Wash Buffer (Item L): 10ml vial of 10x concentrated buffer
    试剂未包括
    • Real-time PCR instrument, Bio-Rad recommended
    • Precision pipettes to deliver 2 μL to 1 mL volumes
    • Adjustable 1-25 mL pipettes for reagent preparation
    • 100 mL and 1 liter graduated cylinders
    • Absorbent paper
    • Distilled or deionized water
    • Log-log graph paper or computer and software for data analysis
    • Tubes to prepare standard or sample dilutions
    • Heating block or water bath capable of 80°C
    Featured
    Discover our best selling C9 ELISA Kit
    Top Product
    Discover our top product C9 ELISA Kit
  • 应用备注
    Optimal working dilution should be determined by the investigator.
    说明

    Features:
    - Excellent for follow up/confirmation of antibody array data
    - Pre-coated 96 well plate
    - Strip plate format minimizes waste
    - Complete kit includes all necessary reagents
    - 10x more sensitive than ELISA
    - Reproducible and reliable
    - Optimized for serum, plasma, urine and cell culture medium
    - 1/10th the sample volume of an ELISA

    Research Applications:
    - Detection of quantitative protein levels in biological fluids
    - Validation of antibody array results
    - Validation of biomarker discovery studies

    实验流程
    1. Prepare all reagents, samples and standards as instructed
    2. Add 25 μL standard or sample to each well. Incubate for 2.5 hours at room temperature or overnight at 4°C
    3. Add 25 μL detection affinity reagent to each well. Incubate 1 hour at room temperature
    4. Add 25μL of IQELISA Detection Reagent to each well. Incubate 1 hour
    5. Add 15μL Primer solution 10μL of PCR master mix to each well
    6. Run real-time PCR
    限制
    仅限研究用
  • 储存条件
    4 °C,-20 °C,-80 °C
    储存方法
    May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.
    有效期
    6 months
  • 抗原 See all C9 IQ-ELISA Kits
    C9 (Complement Component C9 (C9))
    别名
    Complement Component C9 (C9 产品)
    别名
    LOC100037951 IQ-ELISA Kit, LOC100136130 IQ-ELISA Kit, c9 IQ-ELISA Kit, wu:fb60b05 IQ-ELISA Kit, wu:fd50e04 IQ-ELISA Kit, zgc:112272 IQ-ELISA Kit, complement C9 IQ-ELISA Kit, complement component 9 IQ-ELISA Kit, complement component 9 L homeolog IQ-ELISA Kit, C9 IQ-ELISA Kit, c9 IQ-ELISA Kit, c9.L IQ-ELISA Kit
    基因ID
    735
    UniProt
    P02748
    途径
    Complement System
You are here:
客服