电话:
+86 (0512) 65829739
传真:
+86 (010) 6788 5057
电子邮件:
orders@antibodies-online.cn

IL-6 ELISA 试剂盒

人 IL-6 ELISA Kit, Colorimetric is an assay for quantification of 人 IL-6, that has been mentioned in 1 publication.
产品编号 ABIN5523459
发货至: 中国
Contact our Customer Service for availability and price in your country. Contact Info

Our Local Distributor

中国
北京 101111
No. 88 KeChuang 6th Street
Beijing Economic Technological Development Area
Room 801-803
4A Biotech Co.,Ltd.
Tel +86 (0512) 65829739 传真 +86 (010) 6788 5057

Quick Overview for IL-6 ELISA 试剂盒 (ABIN5523459)

抗原

See all IL-6 (IL6) ELISA试剂盒
IL-6 (IL6) (Interleukin 6 (IL6))

适用

  • 67
  • 46
  • 39
  • 24
  • 23
  • 19
  • 18
  • 15
  • 13
  • 12
  • 11
  • 10
  • 9
  • 4
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
人

检测方法

Colorimetric

实验类型

Sandwich ELISA

检测范围

4.688 pg/mL - 300 pg/mL

应用范围

ELISA

样品类型

Cell Culture Supernatant, Cell Samples, Plasma, Serum, Tissue Lysate
  • 最低检测浓度

    4.688 pg/mL

    原理

    Human IL-6 (Interleukin 6) ELISA Kit

    Analytical Method

    Quantitative

    特异性

    Specifically binds with IL-6 , no obvious cross reaction with other analogues. Recommended Sample Dilution Ratio The following table shows the recommended dilution ratios for this kit for a limited number of samples for your reference only. (The matrix components in serum/plasma will affect the test results, which it need to be diluted at least 1/2 with Sample Dilution Buffer before testing! When the content of other samples is very low, the original solution can be added without dilution, but it is necessary to ensure that the pH is between 6.8 and 8.0, and it does not contain more than 10 % organic solvents or high-concentration protein denaturants.) 1. Common sample validation: Sample Type Recommended Dilution Ratio Content Healthy human serum/plasma (EDTA, Citrate?, heparin) (n=10) 1/2 dilution 1.2-6pg/mL Antigen-positive serum of COVID-19 patients (n=5) 1/2-1/20 dilution 175-856pg/mL Antigen-positive plasma (EDTA) of COVID-19 patients (n=12) 1/2-1/100 dilution 269-1432pg/mL Healthy human saliva (n=9) 1/2 dilution ND-12pg/mL Human peripheral blood mononuclear cells (2 x 10^6 cells/mL) were cultured with 5 %FBS+ 1640 + double antibody +10 μg PHA/mL, and the cell culture supernatant was detected after 48 hours 1/200 dilution 6.9 ng/mL 2. KO sample validation (Detect IL-6 KO A549 cells): Sample Type Dilution Ratio Content Wild A549 cells were stimulated with 20 ng/mL(h.IL-11b) for 24 hours to detect cell culture supernatant 1/40 dilution 1.31 ng/mL KO A549 cells were stimulated with 20 ng/mL(h.IL-11b) for 24 hours to detect cell culture supernatants 1/2 dilution ND KO A549 cells were treated with 20 ng/mL(H.IL-11b) for 24 hours and then cultured with 5 μg/mL Brefeldin A (BFA) for 3 hours. Add cell lysis buffer(Catalogue No.:E050), collect the lysate solution (total protein concentration measured by BCA assay: 2.51 mg/mL) to detect. 1/2 dilution ND Note:ND is lower than the sensitivity of the kit and was not detected 3. Capture antibody and detection antibody by WB KO validation (Detect IL-6 KO A549 cells):

    灵敏度

    2.813 pg/mL

    组件

    • ELISA Microplate(Dismountable)
    • Lyophilized Standard
    • Biotin-labeled Antibody
    • HRP-Streptavidin Conjugate(SABC
    • 100X)
    • TMB Substrate
    • Sample Dilution Buffer
    • Stop Solution
    • Plate Sealer
    • Product Description

    试剂未包括

    • Microplate reader (wavelength: 450nm)
    • 37 °C incubator (CO2 incubator for cell culture is not recommenced.)
    • Automated plate washer or multi-channel pipette/5 mL pipettor
    • Precision single (0.5-10μL
    • 5-50μL
    • 20-200μL
    • 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
    • Sterile tubes and Eppendorf tubes with disposable tips
    • Absorbent paper and loading slot
    • Deionized or distilled water
  • 应用备注

    Optimal working dilution should be determined by the investigator.

    说明

    Sandwich ELISA, Double Antibody

    样本量

    100 μL

    实验时间

    4 h

    板类型

    Pre-coated

    实验流程

    Step 1: Add 100 µL standard or sample into each well, seal the plate and statically incubate for 90 minutes at 37 °C. Washing: Wash the plate twice without immersing. Step 2: Add 100 µL biotin-antibody working solution, seal the plate and statically incubate for 60 minutes at 37 °C. Washing: Wash the plate three times and immerse for 1 min each time. Step 3: Add 100 µL HRP-Streptavidin Conjugate (SABC) working solution, seal the plate and statically incubate for 30 minutes at 37 °C. Washing: Wash the plate five times and immerse for 1 min each time. Step 4: Add 90 µL TMB substrate solution, seal the plate and statically incubate for 10-20 minutes at 37 °C. (Accurate TMB visualization control is required.) Step 5: Add 50 µL stop solution. Read at 450nm immediately and calculate.

    限制

    仅限研究用
  • 注意事项

    Avoid direct light exposure to antibody solutions

    储存条件

    4 °C

    储存方法

    Store sealed Kit at 2-8° C. Do Not Cryopreserve. Store ELISA Microplate for 1 month at 2-8°C, Store for 12 month at -20°C. Put the leftover strips into a sealed foil bag with the desiccant

    有效期

    12 months
  • Kim, Kim, Kim: "The effects of a single bout pilates exercise on mRNA expression of bone metabolic cytokines in osteopenia women." in: Journal of exercise nutrition & biochemistry, Vol. 18, Issue 1, pp. 69-78, (2015) (PubMed).

  • 抗原 See all IL-6 (IL6) ELISA试剂盒

    IL-6 (IL6) (Interleukin 6 (IL6))

    别名

    IL-6

    背景

    Interleukin-6, IL-6, B-cell stimulatory factor 2, BSF-2, CTL differentiation factor, CDF, Hybridoma growth factor, Interferon beta-2, IFN-beta-2, IL6, IFNB2

    UniProt

    P05231

    途径

    TLR signaling, Hormone Transport, Negative Regulation of Hormone Secretion, Myometrial Relaxation and Contraction, Positive Regulation of Immune Effector Process, Production of Molecular Mediator of Immune Response, Regulation of Carbohydrate Metabolic Process, Autophagy, Cell RedoxHomeostasis, Cancer Immune Checkpoints, Inflammasome
You are here: