电话:
+86 (0512) 65829739
传真:
+86 (010) 6788 5057
电子邮件:
orders@antibodies-online.cn

MICA ELISA 试剂盒

人 MICA ELISA Kit, Colorimetric is an assay for quantification of 人 MICA.
产品编号 ABIN8070044
发货至: 中国
Contact our Customer Service for availability and price in your country. Contact Info

Our Local Distributor

中国
北京 101111
No. 88 KeChuang 6th Street
Beijing Economic Technological Development Area
Room 801-803
4A Biotech Co.,Ltd.
Tel +86 (0512) 65829739 传真 +86 (010) 6788 5057

Quick Overview for MICA ELISA 试剂盒 (ABIN8070044)

抗原

See all MICA ELISA试剂盒
MICA (MHC Class I Polypeptide-Related Sequence A (MICA))

抗原表位

S-acylated, total

适用

  • 21
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1

检测方法

Colorimetric

实验类型

Sandwich ELISA

应用范围

ELISA

样品类型

Cell Lysate, Tissue Lysate
  • 原理

    Measures s-acylated MICA and total MICA in human cell and tissue lysates, enabling precise assessment of MICA s-acylation by ELISA. This assay can be developed for other species (mouse, rat, etc.) upon request. Contact techsupport@raybiotech.com.

    Analytical Method

    Quantitative

    组件

      Size / Qty
        • Microplate Coated With Anti-Pan-MICA Antibody
        • Positive Control
        • HRP-Conjugated Streptavidin
        • 200 μL
        • Wash Buffer
        • Assay Diluent
        • Lysis Buffer
        • TMB One-Step Substrate Reagent
        • Stop Solution
        • S-Acylation Buffer A
        • S-Acylation Buffer B
        • S-Acylation Buffer C
        • S-Acylation Buffer D
        • S-Acylation Blocking Reagent
        • S-Acylation Reduction Reagent
        • S-Acylation Labeling Reagent

    试剂未包括

    • Acetone (pre-chilled (-20 °C))
    • Microplate reader capable of measuring absorbance at 450 nm
    • Protease and Phosphatase inhibitors
    • Precision pipettes to deliver 2 μL to 1 mL volumes
    • Adjustable 1-25 mL pipettes for reagent preparation
    • 100 mL and 1 liter graduated cylinders
    • Log-log graph paper or computer and software for ELISA data analysis
    • Absorbent paper
    • Tubes to prepare positive control or sample dilutions
    • Distilled or deionized water
    • Shaker
  • 应用备注

    Optimal working dilution should be determined by the investigator.

    板类型

    Pre-coated

    实验流程

    1. Prepare all reagents, samples and Positive Control as instructed.
    2. Block unmodified free cysteines using prepared S-Acylation Blocking Buffer at 50 °C with gentle rocking.
    3. Precipitate proteins with ice-cold acetone.
    4. Wash protein pellet twice with cold acetone/water mixture.
    5. Resuspend protein pellets in Buffers and adding Reducing and Labeling Reagents.
    6. Precipitate proteins with ice-cold acetone.
    7. Resuspend protein pellets.
    8. Add 100 μL sample and Positive Control to each well. Incubate 2.5 hours at room temperature or overnight at 4 °C with gentle shaking.
    9. Add 100 μL prepared HRP-Conjugated Streptavidin solution. Incubate for 1 hour at room temperature with gentle shaking.
    10. Add 100 μL TMB One-Step Substrate Reagent to each well. Incubate 30 minutes at room temperature.
    11. Add 50 μL Stop Solution to each well. Read at 450 nm immediately.

    限制

    仅限研究用
  • 储存条件

    -20 °C

    储存方法

    The entire kit may be stored at -20°C for up to 6 months from the date of shipment. Avoid repeated freeze-thaw cycles.
  • 抗原 See all MICA ELISA试剂盒

    MICA (MHC Class I Polypeptide-Related Sequence A (MICA))

    别名

    MICA

    背景

    Gene Symbols: MICA, PERB11.1

    Background: The S-Acylated MICA ELISA Kit uses a modified "biotin-switch" method to allow for the direct visualization of human S-Acylated MICA by ELISA. In this S-Acylation biotin switch assay, unmodified free cysteines are first blocked. S-Acylated cysteines are then selectively reduced for specific labeling with biotin-maleimide reagents, which irreversibly bind to the cysteine thiol that was S-Acylated. Biotinylation of the newly formed thiol groups can then be detected by ELISA. An anti-pan MICA antibody has been coated onto a 96-well plate. Biotinylated samples are pipetted into the wells, and MICA present in a sample is bound to the wells by the immobilized antibody. The wells are washed, and HRP-conjugated streptavidin is used to detect S-Acylated MICA. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of S-Acylated MICA bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm.

    Protein Name (Synonyms): MHC class I polypeptide-related sequence A (MIC-A)

    基因ID

    100507436

    UniProt

    Q29983

    途径

    Activation of Innate immune Response, Transition Metal Ion Homeostasis, Human Leukocyte Antigen (HLA) in Adaptive Immune Response
You are here: