电话:
400-7060-959
传真:
+86 10 56315212-8813
电子邮件:
orders@antibodies-online.cn

C5A ELISA 试剂盒

High Sensitivity C5a 适用: 小鼠 Colorimetric Sandwich ELISA 78 pg/mL - 5000 pg/mL Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
产品编号 ABIN5564725
发货至: 中国
  • 抗原 See all C5A (C5a) ELISA试剂盒
    C5A (C5a) (Complement Component 5a (C5a))
    适用
    • 7
    • 6
    • 4
    • 3
    • 3
    • 3
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    小鼠
    检测方法
    Colorimetric
    实验类型
    Sandwich ELISA
    检测范围
    78 pg/mL - 5000 pg/mL
    最低检测浓度
    78 pg/mL
    应用范围
    ELISA
    样品类型
    Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
    Analytical Method
    Quantitative
    特异性

    This assay has high sensitivity and excellent specificity for detection of High Sensitive Complement Component 5a (C5a).
    No significant cross-reactivity or interference between High Sensitive Complement Component 5a (C5a) and analogues was observed.

    灵敏度
    35 pg/mL
    质量等级
    High Sensitivity
    组件
    • Pre-coated, ready to use 96-well strip plate
    • Plate sealer for 96 wells
    • Standard Diluent
    • Assay Diluent A
    • Assay Diluent B
    • Stop Solution
    • Standard
    • Detection Reagent A
    • Detection Reagent B
    • TMB Substrate
    • Wash Buffer (30 x concentrate)
    • Instruction manual
    试剂未包括
    • Microplate reader with 450 nm filter.
    • Precision single or multi-channel pipettes and disposable tips.
    • Eppendorf Tubes for diluting samples.
    • Deionized or distilled water.
    • Absorbent paper for blotting the microtiter plate.
    • Container for Wash Solution
    Featured
    Discover our best selling C5a ELISA Kit
    Top Product
    Discover our top product C5a ELISA Kit
  • 实验时间
    3 h
    板类型
    Pre-coated
    实验流程
    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive Complement Component 5a (C5a). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive Complement Component 5a (C5a). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive Complement Component 5a (C5a), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of High Sensitive Complement Component 5a (C5a) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
    实验流程
    1. Prepare all reagents, samples and standards,
    2. Add 100μL standard or sample to each well. Incubate 2 hours at 37 °C,
    3. Aspirate and add 100μL prepared Detection Reagent A. Incubate 1 hour at 37 °C,
    4. Aspirate and wash 3 times,
    5. Add 100μL prepared Detection Reagent B. Incubate 30 minutes at 37 °C,
    6. Aspirate and wash 5 times,
    7. Add 90μL Substrate Solution. Incubate 10-20 minutes at 37 °C,
    8. Add 50μL Stop Solution. Read at 450nm immediately.
    实验精密度

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Complement Component 5a (C5a) were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Complement Component 5a (C5a) were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    限制
    仅限研究用
  • 注意事项
    The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
    注意事项
    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
    储存条件
    4 °C
    储存方法
    • For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
    • For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
      Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit.
    • For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.
    有效期
    6 months
  • 抗原 See all C5A (C5a) ELISA试剂盒
    C5A (C5a) (Complement Component 5a (C5a))
    Abstract
    C5a 产品
    别名
    C5a ELISA Kit, C5b ELISA Kit, CPAMD4 ELISA Kit, Hc ELISA Kit, RGD1561905 ELISA Kit, complement C5 ELISA Kit, C5 ELISA Kit
    UniProt
    P06684
    途径
    Complement System, Carbohydrate Homeostasis
You are here:
客服