PLG ELISA 试剂盒

PLG 适用: Cow Colorimetric Competition ELISA Plasma, Serum
产品编号 ABIN1440254
发货至: 中国
  • 抗原 See all PLG ELISA试剂盒
    PLG (Plasminogen (PLG))
    适用
    • 6
    • 4
    • 4
    • 4
    • 3
    • 3
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    Cow
    检测方法
    Colorimetric
    实验类型
    Competition ELISA
    最低检测浓度
    ~0.3 µg/mL
    应用范围
    ELISA
    原理
    The AssayMax Bovine Plasminogen ELISA kit is designed for detection of bovine plasminogen in plasma, serum, and cell culture supernatants. This assay employs a quantitative competitive enzyme immunoassay technique that measures Plasminogen in less than 3 hours. A polyclonal antibody specific for Plasminogen has been pre-coated onto a 96-well microplate with removable strips. Plasminogen in standards and samples is competed by a biotinylated Plasminogen sandwiched by the immobilized antibody and streptavidin-peroxidase conjugate. All unbound material is then washed away and a peroxidase enzyme substrate is added. The color development is stopped and the intensity of the color is measured.
    品牌
    AssayMax
    样品类型
    Serum, Plasma
    Analytical Method
    Quantitative
    交叉反应 (详细)
    Cross-Reactivity: Canine 2%, Monkey 2%, Rat 4%, Human 4%, Swine 4%, Rabbit 0.5%, Mouse 2%.
    This assay recognizes both natural and recombinant bovine plasminogen.
    产品特性
    Standard Added Value: 0.6 - 6 µg/mL
    组件
    Plasminogen Microplate: A 96-well polystyrene microplate (12 strips of 8 wells) coated with a polyclonal antibody against bovine plasminogen. 2
    Sealing Tapes: Each kit contains 3 pre-cut, pressure-sensitive sealing tapes that can be cut to fit the format of the individual assay.
    Plasminogen Standard: Bovine plasminogen in a buffered protein base (24 µg, lyophilized).
    Biotinylated Plasminogen: 1 vial, lyophilized.
    EIA Diluent Concentrate (10x): A 10-fold concentrated buffered protein base (30 mL).
    Wash Buffer Concentrate (20x): A 20-fold concentrated buffered surfactant (30 mL).
    Streptavidin-Peroxidase Conjugate (SP Conjugate): A 100-fold concentrate (80 µL).
    Chromogen Substrate: A ready-to-use stabilized peroxidase chromogen substrate tetramethylbenzidine (8 mL).
    Stop Solution: A 0.5 N hydrochloric acid to stop the chromogen substrate reaction (12 mL).
    试剂未包括
    Microplate reader capable of measuring absorbance at 450 nm
    Pipettes (1-20 µL, 20-200 µL, 200-1000 µL and multiple channel)
    Deionized or distilled reagent grade water
    Featured
    Discover our best selling PLG ELISA Kit
    Top Product
    Discover our top product PLG ELISA Kit
  • 实验时间
    < 3 h
    板类型
    Pre-coated
    试剂准备

    Freshly dilute all reagents and bring all reagents to room temperature before use.
    EIA Diluent Concentrate (10x): If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved. Dilute the EIA Diluent 1:10 with reagent grade water. Store for up to 1 month at 2-8°C.
    Standard Curve: Reconstitute the 24 µg of bovine Plasminogen Standard with 1 mL of EIA Diluent to produce 24 µg/mL of solution. Allow the standard to sit for 10 minutes with gentle agitation prior to making dilutions. Prepare duplicate or triplicate standard points by serially diluting the standard solution (24 µg/mL)1:2 with equal volume of EIA Diluent to produce 12, 6, 3, 1.5, 0.75, and 0.375 3 µg/mL of solutions. EIA Diluent serves as the zero standard (0 µg/mL). Any remaining solution should be frozen at -20°C.
    Biotinylated Plasminogen (2x): Dilute Biotinylated Plasminogen with 4 mL EIA Diluent to produce a 2-fold stock solution. Allow the biotin to sit for 10 minutes with gentle agitation prior to making dilutions. The stock solution should be further diluted 1:2 with EIA Diluent. Any remaining solution should be frozen at -20°C.
    Wash Buffer Concentrate (20x): If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved. Dilute the Wash Buffer Concentrate 1:20 with reagent grade water.
    SP Conjugate (100x): Spin down the SP Conjugate briefly and dilute the desired amount of the conjugate 1:100 with EIA Diluent. Any remaining solution should be frozen at -20°C.

    样品制备

    Plasma: Collect plasma using one-tenth volume of 0.1 M sodium citrate as an anticoagulant. Centrifuge samples at 2000 x g for 10 minutes and assay. Dilute plasma 1:80 into EIA Diluent. The undiluted samples can be stored at -20°C or below for up to 3 months. Avoid repeated freeze-thaw cycles. (EDTA or Heparin can also be used as anticoagulant.)
    Serum: Samples should be collected into a serum separator tube. After clot formation, centrifuge samples at 2000 x g for 10 minutes. Remove serum and assay. Dilute serum 1:80 into EIA Diluent. The undiluted samples can be stored at -20°C or below for up to 3 months. Avoid repeated freeze- thaw cycles.

    实验流程

    Prepare all reagents, working standards and samples as instructed. Bring all reagents to room temperature before use. The assay is performed at room temperature (20-30°C).
    Remove excess microplate strips from the plate frame and return them immediately to the foil pouch with desiccant inside. Reseal the pouch securely to minimize exposure to water vapor and store in a vacuum desiccator.
    Add 25 µL of standard and/or sample per well, and immediately add 25 µL of Biotinylated Plasminogen to each well (on top of the standard or sample). Cover wells with a sealing tape and incubate for two hours at room temperature. Start the timer after the last sample addition.
    Wash five times with 200 µL of Wash Buffer manually. Invert the plate each time and decant the contents, hit it 4-5 times on absorbent paper towel to completely remove the liquid. If using a machine wash six times with 300 µL of Wash Buffer and then invert the plate, decant the contents, hit it 4-5 times on absorbent paper towel to completely remove the liquid.
    Add 50 µL of Streptavidin-Peroxidase Conjugate to each well and incubate for 30 minutes. Turn on the microplate reader and set up the program in advance.
    Wash the microplate as described above.
    Add 50 µL of Chromogen Substrate per well and incubate for about 7 minutes or until the optimal blue color density develops. Gently tap plate to ensure thorough mixing and break the bubbles in the well with pipette tip.
    Add 50 µL of Stop Solution to each well. The color will change from blue to yellow.
    Read the absorbance on a microplate reader at a wavelength of 450 nm immediately. If wavelength correction is available, subtract readings at 570 nm from those at 450 nm to correct optical imperfections. Otherwise, read the plate at 450 nm only. Please note that some unstable black particles may be generated at high concentration points after stopping the reaction for about 10 minutes, which will reduce the readings.

    结果分析

    Calculate the mean value of the duplicate or triplicate readings for each standard and sample.
    To generate a standard curve, plot the graph using the standard concentrations on the x-axis and the corresponding mean 450 nm absorbance on the y-axis. The best-fit line can be determined by regression analysis using log-log or four-parameter logistic curve-fit.
    Determine the unknown sample concentration from the Standard Curve and multiply the value by the dilution factor.

    实验精密度
    Intra-assay and inter-assay coefficients of variation were 4.7 % and 7.1 % respectively.
    限制
    仅限研究用
  • 注意事项
    Prepare all reagents (working diluent buffer, wash buffer, standards, biotinylated-protein, and SP conjugate) as instructed, prior to running the assay.
    Prepare all samples prior to running the assay. The dilution factors for the samples are suggested in this protocol. However, the user should determine the optimal dilution factor.
    Spin down the SP conjugate vial before opening and using contents.
    The kit should not be used beyond the expiration date.
    The Stop Solution is an acid solution.
    储存条件
    4 °C/-20 °C
    储存方法
    Store components of the kit at 2-8°C or -20°C upon arrival up to the expiration date.
    Store SP Conjugate at -20°C
    Store Microplate, Diluent Concentrate (10x), Wash Buffer, Stop Solution, and Chromogen Substrate at 2-8°C
    Opened unused microplate wells may be returned to the foil pouch with the desiccant packs. Reseal along zip-seal. May be stored for up to 1 month in a vacuum desiccator.
    Diluent (1x) may be stored for up to 1 month at 2-8°C.
    Store Standard and Biotinylated Protein at 2-8°C before reconstituting with Diluent and at -20°C after reconstituting with Diluent.
  • 抗原 See all PLG ELISA试剂盒
    PLG (Plasminogen (PLG))
    别名
    Plasminogen (PLG 产品)
    别名
    wu:fb70e09 ELISA Kit, PLG ELISA Kit, LPA ELISA Kit, plg ELISA Kit, Ab1-346 ELISA Kit, AI649309 ELISA Kit, Pg ELISA Kit, plasminogen ELISA Kit, plg ELISA Kit, PLG ELISA Kit, Plg ELISA Kit
    背景
    Plasminogen is a single chain glycoprotein zymogen that is synthesized in the liver and circulated in plasma with a molecular weight of 90 kDa. The N-terminal portion of the molecule is made up of five kringle domains that bind to fibrin. The native molecule has an amino-terminal glutamic acid, known as glu-plasminogen, but this can undergo proteolytic cleavage by plasmin to lys-plasminogen. The inactive proenzyme plasminogen is converted to the active enzyme plasmin that ultimately digests fibrin. Tissue-type plasminogen activator (tPA) or urokinase-type plasminogen activator (uPA) catalyzes the activation of plasminogen, while plasminogen activator inhibitors (PAIs) inhibits the activation. The plasminogen system plays a role in macrophage recruitment, arterial stenosis, atherosclerosis, aneurysm formation, skin and corneal wound healing, glomerulonephritis, and neovascularization.
    途径
    Complement System, Lipid Metabolism