电话:
+86 (0512) 65829739
传真:
+86 (010) 6788 5057
电子邮件:
orders@antibodies-online.cn

Anti-Japanese Encephalitis Virus IgM (JEV IgM) ELISA 试剂盒

JEV IgM 适用: Japanese Encephalitis Virus (JEV) Colorimetric Sandwich ELISA Serum
产品编号 ABIN997052
发货至: 中国
  • 抗原
    Anti-Japanese Encephalitis Virus IgM (JEV IgM)
    适用
    Japanese Encephalitis Virus (JEV)
    检测方法
    Colorimetric
    实验类型
    Sandwich ELISA
    应用范围
    ELISA
    原理
    The Japanese Encephalitis IgM ELISA test is for exposure to Japanese Encephalitis Virus (JEV) is an ELISA assay system for the detection of IgM antibodies in human serum to JEV derived recombinant antigen (JERA)
    样品类型
    Serum
    Analytical Method
    Qualitative
    特异性
    100 %
  • 说明

    Limitations of procedure:
    Not for use in diagnostic procedures.
    Since this is an indirect screening method, the presence of false positive and negative results must be considered.
    All reactive samples must be evaluated by a confirmatory test.
    The reagents supplied in this kit are optimized to measure JERA reactive antibody levels in serum
    Serological cross-reactivity across the flavivirus group is common. Certain sera from patients infected with Dengue, West Nile, and Saint Louis virus may give false positive results. Therefore any JE positive sera must be confirmed with other tests.
    In areas where JE and dengue are co-existent, JE positive samples should also be assayed for dengue reactivity. Samples with borderline JE positivity and medium to high dengue reactivity could be suspected for dengue infection and require further confirmatory assays.
    The assay performance characteristics have not been established for visual result determination.
    Results from immunosuppressed patients must be interpreted with caution.
    Assay results should be interpreted only in the context of other laboratory findings and the total clinical status of the patient.
    This kit has not been optimized for vaccine induced seroconversion studies.
    The use of JE Detect IgM kit for vaccine induced seroconvesion studies may lead to many "Equivocal

    样本量
    5 μL
    实验时间
    2 - 3 h
    板类型
    Pre-coated
    试剂准备

    Bring all kit reagents and specimens to room temperature (approx. 25 °C) before use. Thoroughly mix the reagents and samples before use by gentle inversion.
    Note:
    All serum, including the experimental, cannot be repeatedly thawed and frozen. For long-term storage, sera should be further aliquoted in a smaller volume and stored at -70 °C. Always quick spin serum sample contained in vials or tubes to collect sample at the bottom.

    Preparation of Reagents
    Preparation of 1X Wash Buffer: Dilute the 10X Wash Buffer to 1X using Biological or High-Grade Water. To prepare a 1X wash buffer solution, mix 120 mL 10X wash buffer with 1080 mL distilled (or deionized) water and rinse out any crystals. Swirl until well mixed and all crystals are dissolved. After diluting to 1X, store at room temperature for up to 6 months. Check for contamination prior to use.
    Microtiter Wells: Select the number of coated wells required for the assay. The remaining unused wells should be placed back quickly into the pouch and stored at 2-8 °C until ready to use or expiration.

    结果分析

    Specificity Studies: The following specificity and sensitivity of the Japanese Encephalitis IgM ELISA kit was derived from two small studies. One was a comparison conducted by the CDC, while the second a JE infected human serum panel provided by CDC. An OD ratio of each sample was calculated (0D450 on JERA/0D450 of control at each dilution). A ratio >10.0 is considered positive for JE infection Positive Convalescent Negative Total JE IgM ELISA + 31 0 0 31 0 1 196 197 Total 31 1 196 228 Note: Specificity panel includes normal and other disease sera, such as sera from patients with autoimmune diseases (ANA, RF, etc, not including Dengue, and WNV, and SLE sera). Limited studies with dengue sera showed cross-reactivity with some sera. One convalescent serum did not show any IgM reactivity. Serological

    限制
    仅限研究用
  • 储存条件
    4 °C
    有效期
    12 months
  • 抗原
    Anti-Japanese Encephalitis Virus IgM (JEV IgM)
    物质类
    Antibody
    背景
    Exposure to JEV causes a disease with a number of symptoms including encephalitis. The Japanese Encephalitis IgM ELISA employs a recombinant antigen called JERA, which can be used as a rapid serological marker for JEV infection. The JERA protein is a recombinant antigen, which consists of a stretch of peptides from different parts of the JEV antigens.