CXCL17 CLIA Kit
Our Local Distributor
北京 101111
Quick Overview for CXCL17 CLIA Kit (ABIN5659912)
抗原
See all CXCL17 CLIA Kits适用
检测方法
实验类型
检测范围
应用范围
样品类型
-
-
最低检测浓度
- 4.12 pg/mL
-
原理
- Human VEGF Co Regulated Chemokine 1 (VCC1) CLIA Kit for detecting VCC1 in serum, plasma
-
Analytical Method
- Quantitative
-
特异性
- This assay has high sensitivity and excellent specificity for detection of VEGF Co Regulated Chemokine 1 (VCC1). No significant cross-reactivity or interference between VEGF Co Regulated Chemokine 1 (VCC1) and analogues was observed.
-
灵敏度
- 1.69 pg/mL
-
组件
-
- Pre-coated, ready to use 96-well strip plate
- Standar
- Detection Reagent A
- Detection Reagent B
- Substrate A
- Substrate B
- Assay Diluent A
- Assay Diluent B
- Wash Buffer (30x concentrate)
- Standard Diluent
- Plate Sealer
- Instruction Manual
-
试剂未包括
-
- Microplate Reader with 450 nm filter
- Single or multi-channel pipettes with high precision and disposable tips
- Microcentrifuge tubes
- Deionized or distilled watter
- Absorbent paper for blotting the microplate
- Container for wash solution
- 0.01 M (or 1x) Phosphate Buffered Saline (PBS), ph 7.0-7.2
-
-
-
-
应用备注
- Optimal working dilution should be determined by the investigator.
-
说明
-
This product is tested and assembled before shipping to ensure that it meets its quality specifications. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.
-
样本量
- 100 μL
-
实验时间
- 3 h
-
板类型
- Pre-coated
-
实验流程
- The microplate provided in this kit has been pre-coated with an antibody specific to VEGF Co Regulated Chemokine 1 (VCC1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to VEGF Co Regulated Chemokine 1 (VCC1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the VEGF Co Regulated Chemokine 1 (VCC1) level in the sample or standard.,
-
实验精密度
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level VEGF Co Regulated Chemokine 1 (VCC1) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level VEGF Co Regulated Chemokine 1 (VCC1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% -
限制
- 仅限研究用
-
-
-
注意事项
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
-
储存条件
- 4 °C,-20 °C
-
储存方法
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
-
有效期
- 12 months
-
-
- CXCL17 (Chemokine (C-X-C Motif) Ligand 17 (CXCL17))
-
别名
- VEGF Co Regulated Chemokine 1
-
背景
- Gene Aliases: CXCL17, SCYB17, DMC, Chemokine C-X-C-Motif Ligand 7, Dendritic cell and monocyte chemokine-like protein
-
基因ID
- 284340
-
UniProt
- Q6UXB2
抗原 See all CXCL17 CLIA Kits
-