电话:
+86 (0512) 65829739
传真:
+86 (010) 6788 5057
电子邮件:
orders@antibodies-online.cn

Cetuximab ELISA 试剂盒

This 人, 小鼠, 大鼠 和 猴 Cetuximab ELISA Kit is a Colorimetric ELISA Kit designed to quantify 人, 小鼠, 大鼠 和 猴 Cetuximab.
产品编号 ABIN5012829
发货至: 中国

Quick Overview for Cetuximab ELISA 试剂盒 (ABIN5012829)

抗原

See all Cetuximab products
Cetuximab

适用

人, 小鼠, 大鼠, 猴

检测方法

Colorimetric

实验类型

Sandwich ELISA

应用范围

ELISA

样品类型

Plasma, Serum
  • 原理

    Enzyme immunoassay for the specific quantitative determination of free Cetuximab in serum and plasma

    Analytical Method

    Quantitative

    特异性

    There is no cross reaction with any other proteins present in native human serum. A screening test was performed with 48 different native human sera. All produced OD450/620 nm values (ranged from 0.011 to 0.058) less than the mean OD (0.125) of standard D (6 ng/mL). In addition, binding of Cetuximab is inhibited by recombinant human epidermal growth factor receptor (hEGFR) protein in a concentration dependent manner. Therefore, the ImmunoGuide Cetuximab ELISA (mAb-Based) measures the biologically active free form of Cetuximab, i.e. not pre-occupied by human EGF Receptor. No cross reaction was observed with sera spiked with the other therapeutic antibodies including Infliximab, Adalimumab, Etanercept, Rituximab, Tocilizumab, Trastuzumab, Aflibercept and Bevacizumab at concentrations up to 2 mg/mL. All produced mean OD450/620 nm values ranged from 0.009 to 0. 027.

    组件

    plate, standards, assay buffer, conjugate, TMB, HCl, wash buffer

    试剂未包括

    normal lab equipment for performing ELISA assays
  • 样本量

    20 μL

    实验时间

    1.5 h

    板类型

    Pre-coated

    实验流程

    This ELISA is based on Cetuximab-specific mouse monoclonal antibody (catcher Ab, clone IG-FB7D9). Diluted standards and samples are incubated in the microtiter plate coated with IG-FB7D9 mAb. After incubation, the wells are washed. A horseradish peroxidase (HRP)-conjugated anti-human IgG monoclonal antibody is added and binds to the Fc part of Cetuximab. Following incubation, wells are washed and the bound enzymatic activity is detected by addition of chromogen-substrate. The colour developed is proportional to the amount of Cetuximab in the sample or standard. Results of samples can be determined by using the standard curve. Binding of Cetuximab to the solid phase, pre-coated with IG-FB7D9, is inhibited by recombinant human epidermal growth factor receptor (rh-EGFR) protein in a concentration dependent manner. Therefore, the Cetuximab ELISA kit (mAb-Based) measures the free form of Cetuximab.

    试剂准备

    Just the wash buffer has to be prepared by diluting the stock solution 1:20. All other reagents are ready to use.

    样品收集

    normal serum or plasma collection

    样品制备

    dilute the samples 1:20 with assay buffer

    结果分析

    The results are read from a standard curve.

    实验精密度

    < 10%

    限制

    仅限研究用
  • 储存液

    Sodium azide

    储存条件

    4 °C

    有效期

    24 months
  • 抗原 See all Cetuximab products

    Cetuximab

    别名

    Cetuximab specific

    背景

    The drug Cetuximab (trade name Erbitux®) is a human-mouse chimeric immunoglobulin (Ig) G1 monoclonal antibody (mAb), selectively directed against the epidermal growth factor receptor (EGFR), also known as HER1 or ErbB1. Since its approval by Food and Drug Administration for cancer treatment in 2004, Cetuximab became widely used in the treatment of colorectal and head and neck cancers. Initial studies reported relationships both between Cetuximab cutaneous toxicity and therapeutic effect and between Cetuximab concentrations and cutaneous toxicity. These data provide indirect evidence for the potential interest of therapeutic drug monitoring of Cetuximab, based on the measurement of its serum concentrations in treated patients. Recently it also reported that there is a correlation between Cetuximab trough levels and antitumor response on Cetuximab monotherapy. In this context, identification of biomarkers for (non-) response and risk factors for adverse drug reactions that might be related to serum drug levels and maintaining the effective concentration in order to potentially avoid some side effects with a reliable method might be beneficial.
You are here:
Chat with us!