IgG2c ELISA 试剂盒
Quick Overview for IgG2c ELISA 试剂盒 (ABIN4993517)
抗原
See all IgG2c products适用
检测方法
实验类型
检测范围
应用范围
样品类型
- 
    - 
                                            最低检测浓度
- 3.13 ng/mL
- 
                                            原理
- The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of IgG2c in Rat serum, plasma and other biological fluids
- 
                                            Analytical Method
- Quantitative
- 
                                            特异性
- This kit recognizes natural and recombinantRatIgG2c. No significant cross-reactivity or interference between RatIgG2c and analogues was observed. Note: Limited by existing techniques, cross reaction may still exist, as it is impossible for us to complete the cross-reactivity detection between RatIgG2c and all the analogues.
- 
                                            灵敏度
- 1.88 ng/mL
- 
                                            组件
- 
                        Micro ELISA Plate
 Reference Standard
 Concentrated Biotinylated Detection Ab
 Concentrated HRP Conjugate
 Reference Standard & Sample Diluent
 Biotinylated Detection Ab Diluent
 HRP Conjugate Diluent
 Concentrated Wash Buffer (25×)
 Substrate Reagent
 Stop Solutio
 Plate Sealer
 Product Description
 Certificate of Analysis
- 
                                            试剂未包括
- 
                        Microplate reader with 450nm wavelength filter
 High-precision transferpettor, EP tubes and disposable pipette tips
 37℃ Incubator
 Deionized or distilled water
 Absorbent paper
 Loading slot for Wash Buffer
 
- 
                                            
- 
    
- 
    - 
                                            说明
- 
                        Information on standard material: 
 The formulation of the standard is 0.01 M PBS. The standard contains additives (1 % BSA).
 Information on reagents:
 Reagents include 1 M SO2. Azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials are not used.
 Information on antibodies:
 The provided antibodies and their host vary in different kits. All antibodies are affinity purified
 The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration.
- 
                                            样本量
- 100 µL
- 
                                            板类型
- Pre-coated
- 
                                            实验流程
- This ELISA kit uses Sandwich-ELISA as the method. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to IgG2c. Standards or samples are added to the appropriate micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for IgG2cand Avidin-Horseradish Peroxidase (HRP) conjugate is added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain IgG2c, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of IgG2c.You can calculate the concentration of IgG2cin the samples by comparing the OD of the samples to the standard curve. 6th Edition, revised in June, 2015 www.elabscience.com 4
- 
                                            限制
- 仅限研究用
 
- 
                                            
- 
    - 
                                            注意事项
- All the reagents in the kit should be stored according to the labels on vials. Unused wells should be returned to the foil pouch with the desiccant pack and resealed along entire edge of zip-seal. Substrate Reagent shouldn't be kept at -20 °C (Check!). Exposure of reagents to strong light should be avoided in the process of incubation and storage. All the taps of reagents should be tightened to prevent evaporation and microbial contamination. If not to store reagents according to above suggestions, erroneous results may occur.
- 
                                            储存条件
- 4 °C/-20 °C
- 
                                            储存方法
- The unopened kit can be stored at 4℃ for 1 month. If the kit is not used within 1 month, store the items separately according to the conditions since the kit is received.
 
- 
                                            
- 
    - IgG2c
- 
                                            别名
- Immunoglobulin G2c (IgG2c)
- 
                                            物质类
- Antibody
 抗原 See all IgG2c products
- 
                    
 
                                     
                                     
                                    