PIIINP ELISA 试剂盒

This Colorimetric ELISA kit is designed for the quantitative measurement of 人 PIIINP. There are 31 publications available.
产品编号 ABIN415073
发货至: 中国
Contact our Customer Service for availability and price in your country. Contact Info

Our Local Distributor

中国
北京 101111
No. 88 KeChuang 6th Street
Beijing Economic Technological Development Area
Room 801-803
4A Biotech Co.,Ltd.
Tel +86 (0512) 65829739 传真 +86 (010) 6788 5057

Quick Overview for PIIINP ELISA 试剂盒 (ABIN415073)

抗原

See all PIIINP ELISA试剂盒
PIIINP (Procollagen III N-Terminal Propeptide (PIIINP))

适用

  • 17
  • 12
  • 9
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1

检测方法

Colorimetric

实验类型

Sandwich ELISA

检测范围

0.625 ng/mL - 40 ng/mL

应用范围

ELISA

样品类型

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
  • 最低检测浓度

    0.625 ng/mL

    原理

    The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of PIIINP in Serum,Plasma,Biological Fluids

    Analytical Method

    Quantitative

    特异性

    This assay has high sensitivity and excellent specificity for detection of Procollagen III N-Terminal Propeptide (PIIINP).
    No significant cross-reactivity or interference between Procollagen III N-Terminal Propeptide (PIIINP) and analogues was observed.

    交叉反应 (详细)

    No significant cross-reactivity or interference between Procollagen III N-Terminal Propeptide (PIIINP) and analogues was observed.

    灵敏度

    < 0.241 ng/mL

    组件

    • Pre-coated, 96-well strip plate
    • Plate sealer
    • Standard
    • Standard Diluent
    • Detection Reagent A
    • Assay Diluent A
    • Detection Reagent B
    • Assay Diluent B
    • TMB Substrate
    • Stop Solution
    • Wash Buffer (30X)
    • Instruction manual

    试剂未包括

    • Microplate reader with 450 nm filter.
    • Precision single or multi-channel pipettes and disposable tips.
    • Eppendorf Tubes for diluting samples.
    • Deionized or distilled water.
    • Absorbent paper for blotting the microtiter plate.
    • Container for Wash Solution
  • 应用备注

    • Limited by the current condition and scientific technology, we cannot completely conduct the comprehensive identification and analysis on the raw material provided by suppliers. So there might be some qualitative and technical risks to use the kit.
    • The final experimental results will be closely related to validity of the products, operation skills of the end users and the experimental environments. Please make sure that sufficient samples are available.
    • Kits from different batches may be a little different in detection range, sensitivity and color developing time.
    • Do not mix or substitute reagents from one kit lot to another. Use only the reagents supplied by manufacturer.
    • Protect all reagents from strong light during storage and incubation. All the bottle caps of reagents should be covered tightly to prevent the evaporation and contamination of microorganism.
    • There may be some foggy substance in the wells when the plate is opened at the first time. It will not have any effect on the final assay results. Do not remove microtiter plate from the storage bag until needed.
    • Wrong operations during the reagents preparation and loading, as well as incorrect parameter setting for the plate reader may lead to incorrect results. A microplate plate reader with a bandwidth of 10nm or less and an optical density range of 0-3 O.D. or greater at 450 ± 10nm wavelength is acceptable for use in absorbance measurement. Please read the instruction carefully and adjust the instrument prior to the experiment.
    • Even the same operator might get different results in two separate experiments. In order to get better reproducible results, the operation of every step in the assay should be controlled. Furthermore, a preliminary experiment before assay for each batch is recommended.
    • Each kit has been strictly passed Q.C test. However, results from end users might be inconsistent with our in-house data due to some unexpected transportation conditions or different lab equipments. Intra-assay variance among kits from different batches might arise from above factors, too.
    • Kits from different manufacturers for the same item might produce different results, since we have not compared our products with other manufacturers.

    说明

    Information on standard material:
    The standard might be recombinant protein or natural protein, that will depend on the specific kit. Moreover, the expression system is E.coli or yeast or mammal cell. There is 0.05% proclin 300 in the standard as preservative.

    Information on reagents:
    The stop solution used in the kit is sulfuric acid with concentration of 1 mol/L. And the wash solution is TBS. The standard diluent contains 0.02 % sodium azide, assay diluent A and assay diluent B contain 0.01% sodium azide. Some kits can contain is BSA in them.

    Information on antibodies:
    The provided antibodies and their host vary in different kits.

    样本量

    100 μL

    实验时间

    3 h

    板类型

    Pre-coated

    实验流程

    1. Prepare all reagents, samples and standards;
    2. Add 100µL standard or sample to each well. Incubate 2 hours at 37°C;
    3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
    4. Aspirate and wash 3 times;
    5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
    6. Aspirate and wash 5 times;
    7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
    8. Add 50µL Stop Solution. Read at 450nm immediately.

    实验精密度

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Procollagen III N-Terminal Propeptide (PIIINP) were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Procollagen III N-Terminal Propeptide (PIIINP) were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    限制

    仅限研究用
  • 注意事项

    The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.

    注意事项

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    储存条件

    4 °C

    储存方法

    • For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
    • For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
      Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit.
    • For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.

    有效期

    6 months
  • Mukherjee, Zhelnin, Sanfiz, Pan, Li, Yarde, McCarty, Jarai: "Development and validation of an in vitro 3D model of NASH with severe fibrotic phenotype." in: American journal of translational research, Vol. 11, Issue 3, pp. 1531-1540, (2019) (PubMed).

    Meel, Nethononda, Libhaber, Dix-Peek, Peters, Essop: "Assessment of myocardial fibrosis by late gadolinium enhancement imaging and biomarkers of collagen metabolism in chronic rheumatic mitral regurgitation." in: Cardiovascular journal of Africa, Vol. 29, Issue 3, pp. 150-154, (2019) (PubMed).

    Li, Zhang, Sun, Li, Yu, Fu, Chen: "Circulating matrix metalloproteinases and procollagen propeptides in inguinal hernia." in: Hernia : the journal of hernias and abdominal wall surgery, Vol. 22, Issue 3, pp. 541-547, (2019) (PubMed).

    Rubiś, Wiśniowska-Smiałek, Wypasek, Rudnicka-Sosin, Hlawaty, Leśniak-Sobelga, Kostkiewicz, Podolec et al.: "12-month patterns of serum markers of collagen synthesis, transforming growth factor and connective tissue growth factor are similar in new-onset and chronic dilated cardiomyopathy in patients both ..." in: Cytokine, Vol. 96, pp. 217-227, (2018) (PubMed).

    Abdul Alim, Domeij-Arverud, Nilsson, Edman, Ackermann: "Achilles tendon rupture healing is enhanced by intermittent pneumatic compression upregulating collagen type I synthesis." in: Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, Vol. 26, Issue 7, pp. 2021-2029, (2018) (PubMed).

    Liu, Chen, Zhen, Ho, Tsang, Yuen, Lam, Tse, Yiu: "Relationship of biomarkers of extracellular matrix with myocardial function in Type 2 diabetes mellitus." in: Biomarkers in medicine, Vol. 11, Issue 7, pp. 569-578, (2018) (PubMed).

    Rubiś, Wiśniowska-Śmiałek, Dziewięcka, Rudnicka-Sosin, Kozanecki, Podolec: "Prognostic value of fibrosis-related markers in dilated cardiomyopathy: A link between osteopontin and cardiovascular events." in: Advances in medical sciences, Vol. 63, Issue 1, pp. 160-166, (2018) (PubMed).

    Sunman, Canpolat, Yorgun, Özkan, Yalçın, Bayrak, Şahiner, Kaya, Özkara, Aytemir, Oto: "Association between reverse electrical remodeling and cardiac fibrosis markers in patients with cardiac resynchronization therapy." in: Turk Kardiyoloji Dernegi arsivi : Turk Kardiyoloji Derneginin yayin organidir, Vol. 46, Issue 2, pp. 84-91, (2018) (PubMed).

    Jotwani, Katz, Ix, Gutiérrez, Bennett, Parikh, Cummings, Sarnak, Shlipak: "Urinary Biomarkers of Kidney Tubular Damage and Risk of Cardiovascular Disease and Mortality in Elders." in: American journal of kidney diseases : the official journal of the National Kidney Foundation, Vol. 72, Issue 2, pp. 205-213, (2018) (PubMed).

    Yılmaz, Yıldırım, Baydar, Altun, Erdem: "Urinary Type III Procollagen Is Associated With Chronic Allograft Dysfunction and Predicts Graft Survival." in: Transplantation proceedings, Vol. 49, Issue 2, pp. 281-287, (2017) (PubMed).

    Sokal, Lenarczyk, Kowalski, Mitrega, Pluta, Stabryla-Deska, Streb, Urbanik, Krzeminski, Kalarus: "Prognostic value of collagen turnover biomarkers in cardiac resynchronization therapy: A subanalysis of the TRUST CRT randomized trial population." in: Heart rhythm : the official journal of the Heart Rhythm Society, Vol. 13, Issue 5, pp. 1088-95, (2016) (PubMed).

    Rubiś, Wiśniowska-Śmialek, Wypasek, Biernacka-Fijalkowska, Rudnicka-Sosin, Dziewiecka, Faltyn, Khachatryan, Karabinowska, Kozanecki, Tomkiewicz-Pająk, Podolec: "Fibrosis of extracellular matrix is related to the duration of the disease but is unrelated to the dynamics of collagen metabolism in dilated cardiomyopathy." in: Inflammation research : official journal of the European Histamine Research Society ... [et al.], Vol. 65, Issue 12, pp. 941-949, (2016) (PubMed).

    Lin, Kuo, Lee, Chou, Chen, Yeh, Huang, Hung, Liu, Ho, Wu: "5-methoxytryptophan is a potential marker for post-myocardial infarction heart failure - a preliminary approach to clinical utility." in: International journal of cardiology, Vol. 222, pp. 895-900, (2016) (PubMed).

    Rubiś, Wiśniowska-Śmiałek, Biernacka-Fijałkowska, Rudnicka-Sosin, Wypasek, Kozanecki, Dziewięcka, Faltyn, Karabinowska, Khachatryan, Hlawaty, Leśniak-Sobelga, Kostkiewicz, Płazak, Podolec: "Left ventricular reverse remodeling is not related to biopsy-detected extracellular matrix fibrosis and serum markers of fibrosis in dilated cardiomyopathy, regardless of the definition used for LVRR." in: Heart and vessels, Vol. 32, Issue 6, pp. 714-725, (2016) (PubMed).

    Buko, Lukivskaya, Naruta, Belonovskaya, Tauschel: "Protective Effects of Norursodeoxycholic Acid Versus Ursodeoxycholic Acid on Thioacetamide-induced Rat Liver Fibrosis." in: Journal of clinical and experimental hepatology, Vol. 4, Issue 4, pp. 293-301, (2015) (PubMed).

    Bielecka-Dabrowa, Michalska-Kasiczak, Gluba, Ahmed, Gerdts, von Haehling, Rysz, Banach: "Biomarkers and echocardiographic predictors of myocardial dysfunction in patients with hypertension." in: Scientific reports, Vol. 5, pp. 8916, (2015) (PubMed).

    Bielecka-Dabrowa, Gluba-Brzózka, Michalska-Kasiczak, Misztal, Rysz, Banach: "The multi-biomarker approach for heart failure in patients with hypertension." in: International journal of molecular sciences, Vol. 16, Issue 5, pp. 10715-33, (2015) (PubMed).

    Page, Charles, Piccinini, Nicolaidou, Taylor, Midwood: "Raised circulating tenascin-C in rheumatoid arthritis." in: Arthritis research & therapy, Vol. 14, Issue 6, pp. R260, (2014) (PubMed).

    Durnea, Khashan, Kenny, Durnea, Smyth, OReilly: "Prevalence, etiology and risk factors of pelvic organ prolapse in premenopausal primiparous women." in: International urogynecology journal, Vol. 25, Issue 11, pp. 1463-70, (2014) (PubMed).

    Banerjee, Mukherjee, Ghosh, Biswas, Dutta, Pattari, Chatterjee, Bandyopadhyay: "Clinical significance of markers of collagen metabolism in rheumatic mitral valve disease." in: PLoS ONE, Vol. 9, Issue 3, pp. e90527, (2014) (PubMed).

  • 抗原 See all PIIINP ELISA试剂盒

    PIIINP (Procollagen III N-Terminal Propeptide (PIIINP))

    别名

    PIIINP

    背景

    P3NP, N-Propeptide Of Type III Procollagen, Procollagen III Amino Terminal Propeptide

    UniProt

    P02461