PICP ELISA 试剂盒

The 人 PICP ELISA Kit (ABIN414990) is a Colorimetric ELISA Kit designed to quantify 人 PICP. This ELISA Kit has been cited in 13 publications.
产品编号 ABIN414990
发货至: 中国
Contact our Customer Service for availability and price in your country. Contact Info

Our Local Distributor

中国
北京 101111
No. 88 KeChuang 6th Street
Beijing Economic Technological Development Area
Room 801-803
4A Biotech Co.,Ltd.
Tel +86 (0512) 65829739 传真 +86 (010) 6788 5057

Quick Overview for PICP ELISA 试剂盒 (ABIN414990)

抗原

See all PICP products
PICP (Procollagen I C-Terminal Propeptide (PICP))

适用

  • 12
  • 11
  • 9
  • 2
  • 1
  • 1
  • 1
  • 1

检测方法

Colorimetric

实验类型

Sandwich ELISA

检测范围

0.312 ng/mL - 20 ng/mL

应用范围

ELISA

样品类型

Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
  • 最低检测浓度

    0.312 ng/mL

    原理

    The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of PICP in Serum,Plasma,Biological Fluids

    Analytical Method

    Quantitative

    特异性

    This assay has high sensitivity and excellent specificity for detection of Procollagen I C-Terminal Propeptide (PICP).
    No significant cross-reactivity or interference between Procollagen I C-Terminal Propeptide (PICP) and analogues was observed.

    交叉反应 (详细)

    No significant cross-reactivity or interference between Procollagen I C-Terminal Propeptide (PICP) and analogues was observed.

    灵敏度

    < 0.129 ng/mL

    组件

    • Pre-coated, 96-well strip plate
    • Plate sealer
    • Standard
    • Standard Diluent
    • Detection Reagent A
    • Assay Diluent A
    • Detection Reagent B
    • Assay Diluent B
    • TMB Substrate
    • Stop Solution
    • Wash Buffer (30X)
    • Instruction manual

    试剂未包括

    • Microplate reader with 450 nm filter.
    • Precision single or multi-channel pipettes and disposable tips.
    • Eppendorf Tubes for diluting samples.
    • Deionized or distilled water.
    • Absorbent paper for blotting the microtiter plate.
    • Container for Wash Solution
  • 应用备注

    • Limited by the current condition and scientific technology, we cannot completely conduct the comprehensive identification and analysis on the raw material provided by suppliers. So there might be some qualitative and technical risks to use the kit.
    • The final experimental results will be closely related to validity of the products, operation skills of the end users and the experimental environments. Please make sure that sufficient samples are available.
    • Kits from different batches may be a little different in detection range, sensitivity and color developing time.
    • Do not mix or substitute reagents from one kit lot to another. Use only the reagents supplied by manufacturer.
    • Protect all reagents from strong light during storage and incubation. All the bottle caps of reagents should be covered tightly to prevent the evaporation and contamination of microorganism.
    • There may be some foggy substance in the wells when the plate is opened at the first time. It will not have any effect on the final assay results. Do not remove microtiter plate from the storage bag until needed.
    • Wrong operations during the reagents preparation and loading, as well as incorrect parameter setting for the plate reader may lead to incorrect results. A microplate plate reader with a bandwidth of 10nm or less and an optical density range of 0-3 O.D. or greater at 450 ± 10nm wavelength is acceptable for use in absorbance measurement. Please read the instruction carefully and adjust the instrument prior to the experiment.
    • Even the same operator might get different results in two separate experiments. In order to get better reproducible results, the operation of every step in the assay should be controlled. Furthermore, a preliminary experiment before assay for each batch is recommended.
    • Each kit has been strictly passed Q.C test. However, results from end users might be inconsistent with our in-house data due to some unexpected transportation conditions or different lab equipments. Intra-assay variance among kits from different batches might arise from above factors, too.
    • Kits from different manufacturers for the same item might produce different results, since we have not compared our products with other manufacturers.

    说明

    Information on standard material:
    The standard might be recombinant protein or natural protein, that will depend on the specific kit. Moreover, the expression system is E.coli or yeast or mammal cell. There is 0.05% proclin 300 in the standard as preservative.

    Information on reagents:
    The stop solution used in the kit is sulfuric acid with concentration of 1 mol/L. And the wash solution is TBS. The standard diluent contains 0.02 % sodium azide, assay diluent A and assay diluent B contain 0.01% sodium azide. Some kits can contain is BSA in them.

    Information on antibodies:
    The provided antibodies and their host vary in different kits.

    样本量

    100 μL

    实验时间

    3 h

    板类型

    Pre-coated

    实验流程

    1. Prepare all reagents, samples and standards;
    2. Add 100µL standard or sample to each well. Incubate 2 hours at 37°C;
    3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
    4. Aspirate and wash 3 times;
    5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
    6. Aspirate and wash 5 times;
    7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
    8. Add 50µL Stop Solution. Read at 450nm immediately.

    实验精密度

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Procollagen I C-Terminal Propeptide (PICP) were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Procollagen I C-Terminal Propeptide (PICP) were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    限制

    仅限研究用
  • 注意事项

    The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.

    注意事项

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    储存条件

    4 °C

    储存方法

    • For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
    • For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
      Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit.
    • For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.

    有效期

    6 months
  • Massoullié, Sapin, Ploux, Rossignol, Mulliez, Jean, Marie, Merlin, Pereira, Andronache, Motreff, Chabin, Sellal, Citron, Lusson, Vorilhon, Clerfond, Bordachar, Zannad, Eschalier: "Low fibrosis biomarker levels predict cardiac resynchronization therapy response." in: Scientific reports, Vol. 9, Issue 1, pp. 6103, (2020) (PubMed).

    Abd El-Moneim, Zolaly, Al-Hawsawi, Abdelmoneim, Abosdera: "Age-related changes in biochemical bone profile in thalassemic children." in: Pediatrics and neonatology, Vol. 59, Issue 2, pp. 189-197, (2019) (PubMed).

    Rubiś, Wiśniowska-Smiałek, Wypasek, Rudnicka-Sosin, Hlawaty, Leśniak-Sobelga, Kostkiewicz, Podolec et al.: "12-month patterns of serum markers of collagen synthesis, transforming growth factor and connective tissue growth factor are similar in new-onset and chronic dilated cardiomyopathy in patients both ..." in: Cytokine, Vol. 96, pp. 217-227, (2018) (PubMed).

    Xie, Liao, Yu, Guo, Yang, Ge, Chen, Chen: "Endothelial‑to‑mesenchymal transition in human idiopathic dilated cardiomyopathy." in: Molecular medicine reports, Vol. 17, Issue 1, pp. 961-969, (2018) (PubMed).

    Rubiś, Wiśniowska-Śmiałek, Dziewięcka, Rudnicka-Sosin, Kozanecki, Podolec: "Prognostic value of fibrosis-related markers in dilated cardiomyopathy: A link between osteopontin and cardiovascular events." in: Advances in medical sciences, Vol. 63, Issue 1, pp. 160-166, (2018) (PubMed).

    Cundy, Dray, Delahunt, Hald, Langdahl, Li, Szybowska, Mohammed, Duncan, McInerney-Leo, Wheeler, Roschger, Klaushofer, Rai, Weis, Eyre, Schwarze, Byers: "Mutations That Alter the Carboxy-Terminal-Propeptide Cleavage Site of the Chains of Type I Procollagen Are Associated With a Unique Osteogenesis Imperfecta Phenotype." in: Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research, Vol. 33, Issue 7, pp. 1260-1271, (2018) (PubMed).

    Tenero, Piazza, Sandri, Azzali, Chinellato, Peroni, Boner, Piacentini: "Effect of montelukast on markers of airway remodeling in children with asthma." in: Allergy and asthma proceedings, Vol. 37, Issue 5, pp. 77-83, (2016) (PubMed).

    Szeremeta, Jura-Półtorak, Komosińska-Vassev, Zoń-Giebel, Kapołka, Olczyk et al.: "The association between insulin-like growth factor 1 (IGF-1), IGF-binding proteins (IGFBPs), and the carboxyterminal propeptide of type I procollagen (PICP) in pre- and postmenopausal women with ..." in: Scandinavian journal of rheumatology, Vol. 46, Issue 3, pp. 171-179, (2016) (PubMed).

    Rubiś, Wiśniowska-Śmialek, Wypasek, Biernacka-Fijalkowska, Rudnicka-Sosin, Dziewiecka, Faltyn, Khachatryan, Karabinowska, Kozanecki, Tomkiewicz-Pająk, Podolec: "Fibrosis of extracellular matrix is related to the duration of the disease but is unrelated to the dynamics of collagen metabolism in dilated cardiomyopathy." in: Inflammation research : official journal of the European Histamine Research Society ... [et al.], Vol. 65, Issue 12, pp. 941-949, (2016) (PubMed).

    Rubiś, Wiśniowska-Śmiałek, Biernacka-Fijałkowska, Rudnicka-Sosin, Wypasek, Kozanecki, Dziewięcka, Faltyn, Karabinowska, Khachatryan, Hlawaty, Leśniak-Sobelga, Kostkiewicz, Płazak, Podolec: "Left ventricular reverse remodeling is not related to biopsy-detected extracellular matrix fibrosis and serum markers of fibrosis in dilated cardiomyopathy, regardless of the definition used for LVRR." in: Heart and vessels, Vol. 32, Issue 6, pp. 714-725, (2016) (PubMed).

    Krämer, Niemann, Störk, Frantz, Beer, Ertl, Wanner, Weidemann: "Relation of burden of myocardial fibrosis to malignant ventricular arrhythmias and outcomes in Fabry disease." in: The American journal of cardiology, Vol. 114, Issue 6, pp. 895-900, (2014) (PubMed).

    Morillas, Quiles, de Andrade, Castillo, Tarazón, Roselló, Portolés, Rivera, Bertomeu-Martínez: "Circulating biomarkers of collagen metabolism in arterial hypertension: relevance of target organ damage." in: Journal of hypertension, Vol. 31, Issue 8, pp. 1611-7, (2013) (PubMed).

    Flevari, Theodorakis, Leftheriotis, Kroupis, Kolokathis, Dima, Anastasiou-Nana, Kremastinos: "Serum markers of deranged myocardial collagen turnover: their relation to malignant ventricular arrhythmias in cardioverter-defibrillator recipients with heart failure." in: American heart journal, Vol. 164, Issue 4, pp. 530-7, (2012) (PubMed).

  • 抗原 See all PICP products

    PICP (Procollagen I C-Terminal Propeptide (PICP))

    别名

    PICP

    背景

    P1CP, C-Propeptide Of Type I Procollagen, Procollagen I Carboxy Terminal Propeptide

    UniProt

    P02452
You are here: