AMH ELISA 试剂盒
Our Local Distributor
北京 101111
Quick Overview for AMH ELISA 试剂盒 (ABIN414951)
抗原
See all AMH ELISA试剂盒适用
检测方法
实验类型
检测范围
应用范围
样品类型
-
-
最低检测浓度
- 937.5 pg/mL
-
原理
-
The kit is a competitive inhibition enzyme immunoassay technique for the in vitro quantitative measurement of AMH in human serum, plasma, tissue homogenates, cell lysates, cell culture supernates.
We offer validation data (WB) for the kit components. So you can be sure to order a reliable ELISA kit product composed of high quality reagents. -
Analytical Method
- Quantitative
-
特异性
-
This assay has high sensitivity and excellent specificity for detection of Anti-Mullerian Hormone (AMH).
No significant cross-reactivity or interference between Anti-Mullerian Hormone (AMH) and analogues was observed. -
交叉反应 (详细)
- No significant cross-reactivity or interference between Anti-Mullerian Hormone (AMH) and analogues was observed.
-
灵敏度
- < 354.2 pg/mL
-
组件
-
- Pre-coated, 96-well strip plate
- Plate sealer
- Standard
- Standard Diluent
- Detection Reagent A
- Assay Diluent A
- Detection Reagent B
- Assay Diluent B
- TMB Substrate
- Stop Solution
- Wash Buffer (30X)
- Instruction manual
-
试剂未包括
-
- Microplate reader with 450 nm filter.
- Precision single or multi-channel pipettes and disposable tips.
- Eppendorf Tubes for diluting samples.
- Deionized or distilled water.
- Absorbent paper for blotting the microtiter plate.
- Container for Wash Solution
-
-
-
-
应用备注
-
- Limited by the current condition and scientific technology, we cannot completely conduct the comprehensive identification and analysis on the raw material provided by suppliers. So there might be some qualitative and technical risks to use the kit.
- The final experimental results will be closely related to validity of the products, operation skills of the end users and the experimental environments. Please make sure that sufficient samples are available.
- Kits from different batches may be a little different in detection range, sensitivity and color developing time.
- Do not mix or substitute reagents from one kit lot to another. Use only the reagents supplied by manufacturer.
- Protect all reagents from strong light during storage and incubation. All the bottle caps of reagents should be covered tightly to prevent the evaporation and contamination of microorganism.
- There may be some foggy substance in the wells when the plate is opened at the first time. It will not have any effect on the final assay results. Do not remove microtiter plate from the storage bag until needed.
- Wrong operations during the reagents preparation and loading, as well as incorrect parameter setting for the plate reader may lead to incorrect results. A microplate plate reader with a bandwidth of 10nm or less and an optical density range of 0-3 O.D. or greater at 450 ± 10nm wavelength is acceptable for use in absorbance measurement. Please read the instruction carefully and adjust the instrument prior to the experiment.
- Even the same operator might get different results in two separate experiments. In order to get better reproducible results, the operation of every step in the assay should be controlled. Furthermore, a preliminary experiment before assay for each batch is recommended.
- Each kit has been strictly passed Q.C test. However, results from end users might be inconsistent with our in-house data due to some unexpected transportation conditions or different lab equipments. Intra-assay variance among kits from different batches might arise from above factors, too.
- Kits from different manufacturers for the same item might produce different results, since we have not compared our products with other manufacturers.
-
说明
-
Information on standard material:
The standard might be recombinant protein or natural protein, that will depend on the specific kit. Moreover, the expression system is E.coli or yeast or mammal cell. There is 0.05% proclin 300 in the standard as preservative.
Information on reagents:
The stop solution used in the kit is sulfuric acid with concentration of 1 mol/L. And the wash solution is TBS. The standard diluent contains 0.02 % sodium azide, assay diluent A and assay diluent B contain 0.01% sodium azide. Some kits can contain is BSA in them.
Information on antibodies:
The provided antibodies and their host vary in different kits. -
样本量
- 50 μL
-
实验时间
- 2 h
-
板类型
- Pre-coated
-
实验流程
-
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
-
实验精密度
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Anti-Mullerian Hormone (AMH) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Anti-Mullerian Hormone (AMH) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
-
限制
- 仅限研究用
-
-
-
注意事项
- The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
-
注意事项
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. -
储存条件
- 4 °C
-
储存方法
-
- For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
- For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit. - For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.
-
有效期
- 6 months
-
-
-
: "The impact of uterine artery embolization on ovarian reserve: A systematic review and meta-analysis." in: Acta obstetricia et gynecologica Scandinavica, Vol. 99, Issue 1, pp. 16-23, (2020) (PubMed).
: "The Effect of Systemic Chemotherapy on Ovarian Function: A Prospective Clinical Trial." in: European journal of breast health, Vol. 16, Issue 3, pp. 177-182, (2020) (PubMed).
: "Levels of anti-Müllerian hormone in premenopausal women with the antiphospholipid syndrome and its association with the risk of clinical complications." in: Lupus, Vol. 28, Issue 3, pp. 427-431, (2019) (PubMed).
: "Comparison of the influence of three fibroid treatment options: supracervical hysterectomy, ulipristal acetate and uterine artery embolization on ovarian reserve - an observational study." in: Journal of ovarian research, Vol. 11, Issue 1, pp. 45, (2018) (PubMed).
: "Intrafollicular inflammatory cytokines but not steroid hormone concentrations are increased in naturally matured follicles of women with proven endometriosis." in: Journal of assisted reproduction and genetics, Vol. 34, Issue 3, pp. 357-364, (2017) (PubMed).
: "Prognostic Value of Anti-Müllerian Hormone and Inhibin B in Patients with Premenopausal Hormone Receptor-positive Breast Cancer." in: Anticancer research, Vol. 36, Issue 3, pp. 1051-7, (2016) (PubMed).
: "Can Coenzyme Q10 supplementation protect the ovarian reserve against oxidative damage?" in: Journal of assisted reproduction and genetics, Vol. 33, Issue 9, pp. 1223-30, (2016) (PubMed).
: "The use of serum anti-Mullerian hormone (AMH) levels and antral follicle count (AFC) to predict the number of oocytes collected and availability of embryos for cryopreservation in IVF." in: Journal of endocrinological investigation, Vol. 39, Issue 12, pp. 1459-1464, (2016) (PubMed).
: "Environmental exposure to polycyclic aromatic hydrocarbons (PAHs): The correlation with and impact on reproductive hormones in umbilical cord serum." in: Environmental pollution (Barking, Essex : 1987), Vol. 220, Issue Pt B, pp. 1429-1437, (2016) (PubMed).
: "Are anti-Müllerian hormone and its receptor polymorphism associated with the hormonal condition of undescended testes?" in: Advances in medical sciences, Vol. 61, Issue 2, pp. 288-292, (2016) (PubMed).
: "Maternal serum anti-Müllerian hormone at 11-13 weeks' gestation in the prediction of preeclampsia." in: The journal of maternal-fetal & neonatal medicine, Vol. 28, Issue 8, pp. 865-8, (2015) (PubMed).
: "Anti-Proliferative and Apoptotic Activities of Müllerian Inhibiting Substance Combined with Calcitriol in Ovarian Cancer Cell Lines." in: Yonsei medical journal, Vol. 57, Issue 1, pp. 33-40, (2015) (PubMed).
: "The effect of childhood cancer therapy on ovarian reserve and pubertal development." in: Reproductive biomedicine online, Vol. 30, Issue 2, pp. 175-80, (2015) (PubMed).
: "The effects of isotretinoin on the ovarian reserve of females with acne." in: Gynecological endocrinology : the official journal of the International Society of Gynecological Endocrinology, Vol. 30, Issue 1, pp. 30-3, (2014) (PubMed).
: "Increased expression of antimüllerian hormone and its receptor in endometriosis." in: Fertility and sterility, Vol. 101, Issue 5, pp. 1353-8, (2014) (PubMed).
: "The relationship between Anti-Müllerian hormone and other reproductive parameters in normal women and in women with polycystic ovary syndrome." in: Journal of medicine and life, Vol. 6, Issue 2, pp. 146-50, (2014) (PubMed).
: "Association between AMH, oocyte number and availability of embryos for cryopreservation in IVF." in: In vivo (Athens, Greece), Vol. 27, Issue 6, pp. 877-80, (2013) (PubMed).
: "The influence of circulating anti-Müllerian hormone on ovarian responsiveness to ovulation induction with gonadotrophins in women with polycystic ovarian syndrome: a pilot study." in: Reproductive biology and endocrinology : RB&E, Vol. 11, pp. 115, (2013) (PubMed).
: "Decreased ovarian reserve in female Sprague-Dawley rats induced by isotretinoin (retinoic acid) exposure." in: Reproductive biomedicine online, Vol. 27, Issue 2, pp. 184-91, (2013) (PubMed).
: "Influence of gonadotropin-releasing hormone agonist on the effect of chemotherapy upon ovarian cancer and the prevention of chemotherapy-induced ovarian damage: an experimental study with nu/nu ..." in: Journal of Zhejiang University. Science. B, Vol. 13, Issue 11, pp. 894-903, (2012) (PubMed).
-
-
- AMH (Anti-Mullerian Hormone (AMH))
-
别名
- AMH
-
背景
- MIF, MIH, MIS, Müllerian Inhibiting Factor, Müllerian Inhibiting Hormone, Müllerian Inhibiting Substance
-
UniProt
- P03971
-
途径
- Negative Regulation of Hormone Secretion
抗原 See all AMH ELISA试剂盒
-