CXCR7 ELISA 试剂盒

CXCR7 适用: 人 Colorimetric Sandwich ELISA 0.156 ng/mL - 10 ng/mL Cell Lysate, Plasma, Serum, Tissue Homogenate
产品编号 ABIN1569295
发货至: 中国
  • 抗原 See all CXCR7 ELISA试剂盒
    CXCR7 (Chemokine (C-X-C Motif) Receptor 7 (CXCR7))
    适用
    • 1
    • 1
    • 1
    • 1
    检测方法
    Colorimetric
    实验类型
    Sandwich ELISA
    检测范围
    0.156 ng/mL - 10 ng/mL
    最低检测浓度
    0.156 ng/mL
    应用范围
    ELISA
    原理
    The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of CXCR7 in human serum, plasma, tissue homogenates, cell lysates and other biological fluids.
    样品类型
    Cell Lysate, Plasma, Serum, Tissue Homogenate
    Analytical Method
    Quantitative
    特异性
    This assay has high sensitivity and excellent specificity for detection of this index.
    交叉反应 (详细)
    No significant cross-reactivity or interference between this index and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross- reactivity detection between this index and all the analogues, therefore, cross reaction may still exist.
    灵敏度
    0.062 ng/mL
    组件
    • Pre-coated, ready to use 96-well strip plate
    • Standard (freeze dried)
    • Standard Diluent
    • Detection Reagent A
    • Detection Reagent B
    • Assay Diluent A
    • Assay Diluent B
    • TMB
    • Stop Solution
    • Wash Buffer (30X)
    • Plate sealer for 96 wells
    • Instruction manual
    试剂未包括
    1. Microplate reader with 450 ± 10nm filter.
    2. Precision single or multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. Deionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
    Featured
    Discover our best selling CXCR7 ELISA Kit
    Top Product
    Discover our top product CXCR7 ELISA Kit
  • 样本量
    100 μL
    实验时间
    1 - 4.5 h
    板类型
    Pre-coated
    实验流程
    1. Prepare all reagents, samples and standards
    2. Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
    3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
    4. Aspirate and wash 3 times
    5. Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
    6. Aspirate and wash 5 times
    7. Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
    8. Add 50µL Stop Solution. Read at 450nm immediately.
    实验流程

    The microtiter plate provided in this kit has been pre-coated with an antibody specific to the index. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific to the index. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain the index, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of the index in the samples is then determined by comparing the O.D. of the samples to the standard curve.

    实验精密度
    • Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
    • Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
    • CV(%) = SD/meanX100
    • Intra-assay: CV<10%
    • Inter-assay: CV<12%
    限制
    仅限研究用
  • 注意事项
    The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
    注意事项
    The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
    储存条件
    4 °C,-20 °C
    储存方法
    The Assay Plate, Standard, Detection Reagent A and Detection Reagent B should be stored at -20°C upon being received. After receiving the kit , Substrate should be always stored at 4°C.Other reagents are kept according to the labels on vials. But for long term storage, please keep the whole kit at -20°C. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. The test kit may be used throughout the expiration date of the kit (six months from the date of manufacture). Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
    有效期
    12 months
  • 抗原 See all CXCR7 ELISA试剂盒
    CXCR7 (Chemokine (C-X-C Motif) Receptor 7 (CXCR7))
    别名
    CXCR7 (CXCR7 产品)
    别名
    CMKOR1 ELISA Kit, CXC-R7 ELISA Kit, CXCR-7 ELISA Kit, CXCR7 ELISA Kit, GPR159 ELISA Kit, RDC-1 ELISA Kit, RDC1 ELISA Kit, AW541270 ELISA Kit, Cmkor1 ELISA Kit, Cxcr7 ELISA Kit, Rdc1 ELISA Kit, ackr3 ELISA Kit, cxcr7 ELISA Kit, rdc1 ELISA Kit, xcxcr7 ELISA Kit, atypical chemokine receptor 3 ELISA Kit, ORF 74; similar to Kaposi's sarcoma-associated herpesvirus ORF 74 ELISA Kit, atypical chemokine receptor 3 L homeolog ELISA Kit, ACKR3 ELISA Kit, MmrVgp88 ELISA Kit, Ackr3 ELISA Kit, ackr3.L ELISA Kit
    背景
    Alternative name: ACKR3, RDC1, CMKOR1, GPR159, Chemokine Orphan Receptor 1, Atypical chemokine receptor 3, G-protein coupled receptor 159, G-protein coupled receptor RDC1 homolog
    基因ID
    57007
    UniProt
    P25106
    途径
    Myometrial Relaxation and Contraction, Negative Regulation of intrinsic apoptotic Signaling
You are here: