ACTH ELISA 试剂盒

ACTH 适用: 人 Colorimetric Sandwich ELISA 1.0-416 pg/mL Plasma
产品编号 ABIN1305175
发货至: 中国
  • 抗原 See all ACTH ELISA试剂盒
    ACTH (Adrenocorticotropic hormone (ACTH))
    适用
    • 6
    • 5
    • 3
    • 3
    • 2
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    检测方法
    Colorimetric
    实验类型
    Sandwich ELISA
    检测范围
    1.0-416 pg/mL
    最低检测浓度
    1 pg/mL
    应用范围
    ELISA
    原理
    This test kit is intended for use in the quantitative determination of human adrenocorticotropic hormone (ACTH) in EDTA-plasma. The test is useful for detecting elevated and deficient ACTH levels. Indications for use: Patient may have a higher than normal levels of ACTH with1. Addison's disease or primary adrenal insufficiency2. Congenital adrenal hyperplasia3. Cushing's syndrome4. Cushing's disease5. Multiple endocrine neoplasia (MEN), type I Patient may have a lower than normal levels of ACTH with6. Hypopituitarism and/or secondary adrenal insufficiency7. Adrenal gland tumor8. Other tumors that produce cortisol
    品牌
    ED™
    样品类型
    Plasma
    Analytical Method
    Quantitative
    组件
    1. Anti-ACTH Antibody Coated Microplate
    One vial containing 5 mL ready-to-use buffer. It should be used only for tracer antibody dilution according to the assay procedures. This reagent should be stored at 2-8 °C and is stable until the expiration date on the kit box.
    试剂未包括
    1. Precision single channel pipettes capable of delivering 25 µL, 200 µL, etc.
    2. Disposable pipette tips suitable for above volume dispensing.
    3. Aluminum foil.
    4. Deionized or distilled water.
    5. Plastic microtiter well cover or polyethylene film.
    6. ELISA multichannel wash bottle or automatic (semi-automatic) washing system.
    7. Spectrophotometric microplate reader capable of reading absorbance at 450/650 or 450/620 nm.
    Featured
    Discover our best selling ACTH ELISA Kit
    Top Product
    Discover our top product ACTH ELISA Kit
  • 样本量
    0.4 mL
    实验时间
    4 h
    板类型
    Pre-coated
    实验流程
    This ELISA kit is designed, developed and produced for the quantitative measurement of human ACTH in EDTA-plasma sample. The assay utilizes the two-site sandwich technique with selected antibodies that bind to N-terminal and C-terminal epitopes of ACTH.Assay standards, controls and patient samples are added directly to wells of a microtiter plate that is coated with antibody to the C-terminal of human ACTH. Immediately, a horseradish peroxidase (HRP) conjugated anti N-terminal of human ACTH antibody is added to each well. After the first incubation period, a sandwich of solid-phase polyclonal antibody - human ACTH HRP conjugated monoclonal antibody is formed. The unbound antibodies and buffer matrix are removed in the subsequent washing step. For the detection of this immunocomplex, the well is then incubated with a substrate solution in a timed reaction, which is terminated with an acidic reagent (i.e. ELISA stop solution). The absorbance is then measured in a spectrophotometric microplate reader. The enzymatic activity of the immunocomplex bound to the wall of each microtiter well is directly proportional to the amount of human ACTH in the test sample. A standard curve is generated by plotting the absorbance versus the respective human ACTH concentration for each standard on a point-to-point or 4-parameter curve fitting. The concentration of human ACTH in test samples is determined directly from this standard curve.
    试剂准备

    (1) Prior to use allow all reagents to come to room temperature. Reagents from different kit lot numbers should not be combined or interchanged.
    (2) ELISA Wash Concentrate must be diluted to working solution prior to use. Please see REAGENTS section for details.
    (3) Reconstitute assay standards and controls by adding 2.0 mL of deminerialized water to each standard and control bottle. Allow the standard and controls to sit undisturbed for 5 minutes, and then mix well by inversions or gentle vortexing. One must make sure that all solid is dissolved completely prior to use. These reconstituted standards and controls may be stored at 2- 8 C for up to 24 hours or below ?10 C for long-term storage. Do not exceed 3 freeze-thaw cycles.
    (4) Prepare Tracer Antibody working solution by 1:21 fold dilution of the ACTH Tracer Antibody by adding the tracer antibody into the Tracer Antibody Diluent . Following is a table that outlines the relationship of strips used and antibody mixture prepared. NOTE: the tracer antibody should be prepared just prior to the beginning of the assay.
    (5) Test Configuration
    (6) Place a sufficient number of Anti-ACTH antibody-coated microwell strips in a holder to run human ACTH standards, controls and unknown samples in duplicates.

    样品收集
    Since the circulating ACTH shows a 24 hours circadian rhythms, it is recommended to draw blood sample in the early morning, before 8 a.m. Patients should stop taking steroid drugs before drawing blood sample, at the consultation of their physician. EDTA-plasma is a suitable specimen for human ACTH measurement. A total of 0.4 mL EDTA-plasma is required for duplicate determination of human ACTH with this test kit. Whole blood should be collected using lavender-top Vaccutainer and the plasma separated according to manufacturer?s instruction. The EDTA-plasma should be separated from other cells right after or within one hour of blood collection. The plasma should be transferred to a clean test tube right after centrifugation. Plasma samples should be stored at ? 20 °C if the assay is not to be performed within 3 hours. Avoid more than three times freeze-thaw cycles of specimen. Samples of serum, heparin plasma and citrate plasma should not be used for ACTH measurement.
    实验流程

    (1) Add 200 µL of standards, controls and patient samples into the designated microwells.
    (2) Immediately add 25 µL of HRP Conjugated Anti-ACTH Tracer Antibody mix to each well.
    (3) Seal the plate wells securely, cover with foil or other material to protect from light, and rotate on an ELISA plate shaker (small orbit radius) for 2 hr. 5 minutes at 400 to 450 rpm.
    (4) Wash each well 5 times by dispensing 350 µL of working wash solution into each well and then completely aspirating the contents. Alternatively, an automated microplate washer can be used.
    (5) Add 200 µL of ELISA HRP Substrate into each of the wells.
    (6) Cover the plate with aluminum foil or other material to avoid exposure to light. Incubate plate static, at room temperature for 20 minutes.
    (7) Immediately add 50 µL of ELISA Stop Solution into each of the wells. Mix gently.
    (8) Read the absorbance at 450 nm with reference filter at 620 nm or 650 nm.

    结果分析

    It is recommended to use a point-to-point or 4-parameter standard curve fitting.
    1. Calculate the average absorbance for each pair of duplicate test results.
    2. Subtract the average absorbance of the level 1 standard (0 pg/mL) from the average absorbance of all other readings to obtain corrected absorbance.
    3. The standard curve is generated by the corrected absorbance of all standard levels on the ordinate against the standard concentration on the abscissa using point-to-point or log-log paper. Appropriate computer assisted data reduction programs may also be used for the calculation of results. The human ACTH concentrations for the controls and the patient samples are read directly from the standard curve using their respective corrected absorbance.

    实验精密度
    The intra-assay precision was validated by measuring three control samples with 16 replicate determinations. The inter-assay precision was validated by measuring two control levels in duplicate in 16 individual assays.
    限制
    仅限研究用
  • 注意事项
    The reagents must be used in professional laboratory. Source material for reagents containing bovine serum was derived in the contiguous 48 United States. It was obtained only from healthy donor animals maintained under veterinary supervision and found free of contagious diseases. Wear gloves while performing this assay and handle these reagents as if they are potentially infectious. Avoid contact with reagents containing TMB, hydrogen peroxide, or sulfuric acid. TMB may cause irritation to skin and mucous membranes and cause an allergic skin reaction. TMB is a suspected carcinogen. Sulfuric acid may cause severe irritation on contact with skin. Do not get in eyes, on skin, or on clothing. Do not ingest or inhale fumes. On contact, flush with copious amounts of water for at least 15 minutes. Use Good Laboratory Practices.
    储存条件
    4 °C
  • 抗原 See all ACTH ELISA试剂盒
    ACTH (Adrenocorticotropic hormone (ACTH))
    Abstract
    ACTH 产品
    别名
    ACTH ELISA Kit, BE ELISA Kit, Beta-LPH ELISA Kit, Clip ELISA Kit, Gamma-LPH ELISA Kit, Npp ELISA Kit, Pomc-1 ELISA Kit, Pomc1 ELISA Kit, alpha-MSH ELISA Kit, alphaMSH ELISA Kit, beta-MSH ELISA Kit, gamma-MSH ELISA Kit, CLIP ELISA Kit, LPH ELISA Kit, MSH ELISA Kit, NPP ELISA Kit, POC ELISA Kit, pro-opiomelanocortin-alpha ELISA Kit, proopiomelanocortin ELISA Kit, Pomc ELISA Kit, POMC ELISA Kit
    物质类
    Hormone
    背景
    ACTH is a 39 amino acid polypeptide with a molecular weight of 4540 Dalton. ACTH is secreted from corticotropes in the anterior lobe (or adenohypophysis) of the pituitary gland in response to corticotropin-releasing hormone (CRH) released by the hypothalamus. ACTH is synthesized from pre-pro-opiomelanocortin (pre-POMC). The removal of the signal peptide during translation produces the 241-amino acid polypeptide POMC, which undergoes a series of post-translational modifications such as phosphorylation and glycosylation before it is proteolytically cleaved by endopeptidases to yield various polypeptide fragments with varying physiological activity. ACTH is an important component of the hypothalamic-pituitary-adrenal axis and is often produced in response to biological stress. It stimulates secretion of glucocorticoid steroid hormones from adrenal cortex cells especially in the zona fasciculata of the adrenal. ACTH acts by binding to cell surface ACTH receptors, which are located primarily on adrenocortical cells of the adrenal cortex.