Lambda-IgLC 抗体 (PE)

Lambda-IgLC 适用: 人 FACS 宿主: 小鼠 Monoclonal 1-155-2 PE
产品编号 ABIN775718
发货至: 中国
  • 抗原 See all Lambda-IgLC products
    Lambda-IgLC (lambda Light Chain (Lambda-IgLC))
    适用
    • 26
    • 15
    • 1
    宿主
    • 23
    • 18
    • 1
    小鼠
    克隆类型
    • 22
    • 20
    单克隆
    标记
    • 12
    • 4
    • 3
    • 3
    • 2
    • 2
    • 2
    • 2
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    This Lambda-IgLC antibody is conjugated to PE
    应用范围
    • 19
    • 15
    • 13
    • 13
    • 9
    • 6
    • 6
    • 6
    • 3
    • 1
    • 1
    • 1
    Flow Cytometry (FACS)
    特异性
    The mouse monoclonal antibody 1-155-2 recognizes lambda light chains (22.5 kDa) of human immunoglobulin.
    交叉反应 (详细)
    Human
    纯化方法
    Purified antibody is conjugated with R-phycoerythrin (PE) under optimum conditions. Unconjugated antibody and free fluorochrome are removed by size-exclusion chromatography.
    免疫原
    Human IgA1 lambda myeloma protein
    克隆位点
    1-155-2
    亚型
    IgG1 kappa
  • 应用备注
    Flow cytometry: The reagent is designed for analysis of human blood cells using 10 μL reagent / 100 μL of whole blood or 106 cells in a suspension. The content of a vial (1 ml) is sufficient for 100 tests. Extracellular and intracellular staining.
    说明

    The purified antibody is conjugated with R-Phycoerythrin (PE) under optimum conditions. The conjugate is purified by size-exclusion chromatography and adjusted for direct use. No reconstitution is necessary.

    限制
    仅限研究用
  • 溶解方式
    No reconstitution is necessary.
    缓冲液
    Stabilizing phosphate buffered saline (PBS), pH 7.4, 15 mM sodium azide
    储存液
    Sodium azide
    注意事项
    This product contains Sodium azide: a POISONOUS AND HAZARDOUS SUBSTANCE which should be handled by trained staff only.
    注意事项
    Do not freeze.
    Avoid prolonged exposure to light.
    储存条件
    4 °C
    储存方法
    Store at 2-8°C. Protect from prolonged exposure to light. Do not freeze.
  • Tierens, Holte, Warsame, Ikonomou, Wang, Chan, Delabie: "Low levels of monoclonal small B cells in the bone marrow of patients with diffuse large B-cell lymphoma of activated B-cell type but not of germinal center B-cell type." in: Haematologica, Vol. 95, Issue 8, pp. 1334-41, (2010) (PubMed).

    Bahler, Pindzola, Swerdlow: "Splenic marginal zone lymphomas appear to originate from different B cell types." in: The American journal of pathology, Vol. 161, Issue 1, pp. 81-8, (2002) (PubMed).

    Kubagawa, Gathings, Levitt, Kearney, Cooper: "Immunoglobulin isotype expression of normal pre-B cells as determined by immunofluorescence." in: Journal of clinical immunology, Vol. 2, Issue 4, pp. 264-9, (1983) (PubMed).

  • 抗原
    Lambda-IgLC (lambda Light Chain (Lambda-IgLC))
    别名
    Lambda light chains (Lambda-IgLC 产品)
    背景
    Immunoglobulin classes share the same basic four polypeptide chain structure of two heavy chains (five heavy chains types) and two light chains (kappa, lambda, both having a molecular weight of 22.5 kDa). Kappa and lambda consist of a variable region and a constant region and can easily be differentiated by the antigenic properties of the constant region. The ratio of kappa to lambda is 70:30.,Immunoglobulin lambda, Igl
    分子量
    22.5 kDa