电话:
400-7060-959
传真:
+86 10 56315212-8813
电子邮件:
orders@antibodies-online.cn

MMP 9 ELISA 试剂盒

MMP9 适用: Pig Colorimetric Sandwich ELISA 0.156-10 ng/mL
产品编号 ABIN955938
发货至: 中国
  • 抗原 See all MMP 9 (MMP9) ELISA试剂盒
    MMP 9 (MMP9) (Matrix Metallopeptidase 9 (Gelatinase B, 92kDa Gelatinase, 92kDa Type IV Collagenase) (MMP9))
    适用
    • 12
    • 5
    • 4
    • 3
    • 3
    • 2
    • 2
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    Pig
    检测方法
    Colorimetric
    实验类型
    Sandwich ELISA
    检测范围
    0.156-10 ng/mL
    最低检测浓度
    0.156 ng/mL
    应用范围
    ELISA
    原理
    The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of pig MMP9 in serum, plasma, tissue homogenates, cell culture supernates and other biological fluids.
    Analytical Method
    Quantitative
    特异性
    This assay has high sensitivity and excellent specificity for detection of pig MMP9. No significant cross- reactivity or interference was observed.
    灵敏度
    The minimum detectable dose of pig MMP9 is typically less than 0.041 ng/mL.
    The Sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D. Value of 20 replicates of the zero calibrator plus three standard deviations.
    产品特性
    The microtiter plate provided in this kit has been pre-coated with an antibody specific to MMP9. Calibrators or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for MMP9. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB substrate solution is added to each well. Only those wells that contain MMP9, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulfuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm +/- 2 nm. The concentration of MMP9 in the samples is then determined by comparing the O.D. of the samples to the calibration curve.
    组件
    Pre-coated, ready to use 96-well strip plate (1x)
    Calibrator (lyophilized) (2x)
    Calibrator Diluent (1 x 20 mL)
    Detection Reagent A (1 x 120 µL)
    Detection Reagent B (1 x 120 µL)
    Assay Diluent A (2X concentrate) (1 x 6 mL)
    Assay Diluent B (2X concentrate) (1 x 6 mL)
    TMB Substrate (1 x 9 mL)
    Stop Solution (1 x 6 mL)
    Wash Buffer (30X concentrate) (1 x 20 mL)
    Plate sealer for 96 wells (4x).
    试剂未包括
    1. Microplate reader with 450 +/- 10 nm filter.
    2. Precision single and multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. De-ionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
    Featured
    Discover our best selling MMP9 ELISA Kit
    Top Product
    Discover our top product MMP9 ELISA Kit
  • 说明

    The calibration curve concentrations used for the ELISA's were 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.312 ng/mL, 0.156 ng/mL.

    板类型
    Pre-coated
    结果分析

    Average the duplicate readings for each calibrator, control, and samples and subtract the average zero calibrator optical density. Create a calibration curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a calibration curve by plotting the mean absorbance for each calibrator on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the MMP9 concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. It is recommended to use some related software to do this calculation. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the calibration curve must be multiplied by the dilution factor.

    限制
    仅限研究用
  • 储存条件
    -20 °C
    储存方法
    All the reagents should be kept according to the labels on vials. The Calibrator, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20° C upon being received. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. Opened test kits will remain stable until the expiration date shown, provided it is stored as prescribed above.
    有效期
    The expiry date is stated on the label.
  • 抗原 See all MMP 9 (MMP9) ELISA试剂盒
    MMP 9 (MMP9) (Matrix Metallopeptidase 9 (Gelatinase B, 92kDa Gelatinase, 92kDa Type IV Collagenase) (MMP9))
    别名
    MMP9 (MMP9 产品)
    别名
    CLG4B ELISA Kit, GELB ELISA Kit, MANDP2 ELISA Kit, MMP-9 ELISA Kit, AW743869 ELISA Kit, B/MMP9 ELISA Kit, Clg4b ELISA Kit, pro-MMP-9 ELISA Kit, mmp-9 ELISA Kit, fgMMP-9 ELISA Kit, mmp9 ELISA Kit, ZFMMP-9 ELISA Kit, wu:fb02g06 ELISA Kit, wu:fb07b05 ELISA Kit, wu:fi98c09 ELISA Kit, wu:fj05a08 ELISA Kit, zgc:64165 ELISA Kit, clg4b ELISA Kit, gelb ELISA Kit, mandp2 ELISA Kit, matrix metallopeptidase 9 ELISA Kit, collagenase ELISA Kit, matrix metalloproteinase 9 ELISA Kit, matrix metallopeptidase 9 S homeolog ELISA Kit, MMP9 ELISA Kit, RB3913 ELISA Kit, BPSS0666 ELISA Kit, Sbal_3732 ELISA Kit, Bcer98_0486 ELISA Kit, Shew185_0630 ELISA Kit, Shal_3056 ELISA Kit, Sbal195_0657 ELISA Kit, Lbys_3550 ELISA Kit, Palpr_2084 ELISA Kit, Mmp9 ELISA Kit, mmp9 ELISA Kit, mmp9.S ELISA Kit
    途径
    Cellular Response to Molecule of Bacterial Origin, Positive Regulation of Immune Effector Process, CXCR4-mediated Signaling Events
You are here:
客服