PAR1 IQ-ELISA 试剂盒

F2R 适用: 人 qPCR Sandwich ELISA Cell Culture Supernatant, Plasma, Serum
产品编号 ABIN6386104
发货至: 中国
  • 抗原 See all PAR1 (F2R) IQ-ELISA Kits
    PAR1 (F2R) (Coagulation Factor II (thrombin) Receptor (F2R))
    适用
    • 4
    • 3
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    检测方法
    qPCR
    实验类型
    Sandwich ELISA
    应用范围
    ELISA
    原理
    Human Immunoquantitative (PCR-Based) PAR1 ELISA Kit for cell culture supernatants, plasma, and serum samples.
    样品类型
    Cell Culture Supernatant, Plasma, Serum
    Analytical Method
    Semi-Quantitative
    灵敏度
    0.3 pg/mL
    产品特性
    IQ-ELISAs employ specific capture antibodies coated on a 96-well PCR plate. Standards and samples are pipetted into the wells, the target protein in the standards and samples binds to the immobilized antibody. The wells are washed and the detection affinity reagent is added to the wells where it binds to any captured antigen. The wells are washed, and primers and PCR master mix are added to each well. The plate is placed into a real time PCR instrument for cycling and measurement of DNA amplification. The cycle number where amplification is detected is proportional to the amount of affinity detection reagent that bound to captured antigen in each well.
    组件
    • PAR1 Microplate (Item A): 96 well PCR plate coated with anti-Human PAR1
    • Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution
    • Standards (Item C): 2 vials of recombinant Human PAR1
    • Assay Diluent A (Item D): 30 ml diluent buffer, 0.09% sodium azide as preservative. For Standard/Sample (serum/plasma) diluent
    • Assay Diluent B (Item E): 15 ml of 5x concentrated buffer. For Standard/Sample (cell culture medium/urine) diluent
    • Detection Affinity Reagent for PAR1 (Item F): 2 vials of a 4x concentrated solution of anti-Human PAR1 affinity reagent
    • IQELISA Detection Reagent (Item G): 1.4ml of a 10x concentrated stock
    • Primer Solution (Item I): 1.7 ml vial
    • PCR Master Mix (Item J): 1.2 ml vial
    • PCR Preparation buffer (Item K): 1ml vial of 10x concentrated buffer
    • Final Wash Buffer (Item L): 10ml vial of 10x concentrated buffer
    试剂未包括
    • Real-time PCR instrument, Bio-Rad recommended
    • Precision pipettes to deliver 2 μL to 1 mL volumes
    • Adjustable 1-25 mL pipettes for reagent preparation
    • 100 mL and 1 liter graduated cylinders
    • Absorbent paper
    • Distilled or deionized water
    • Log-log graph paper or computer and software for data analysis
    • Tubes to prepare standard or sample dilutions
    • Heating block or water bath capable of 80°C
    Featured
    Discover our best selling F2R ELISA Kit
    Top Product
    Discover our top product F2R ELISA Kit
  • 应用备注
    The Immuno-Quantitative ELISA (IQELISA) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of only 1/10th the sample volume while also providing 10x more sensitivity than a traditional ELISA.
    说明

    The Immuno-Quantitative ELISA (IQELISA™) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. Also called immuno-PCR, this detection platform results in an assay that is simultaneously familiar and cutting edge. Compared to traditional ELISA, IQELISA™ enables the use of only 1/10th the sample volume while also providing 10x more sensitivity.

    样本量
    25 µL
    板类型
    Pre-coated
    实验流程
    1. Prepare all reagents, samples and standards as instructed
    2. Add 25 μL standard or sample to each well. Incubate for 2.5 hours at room temperature or overnight at 4°C
    3. Add 25 μL detection affinity reagent to each well. Incubate 1 hour at room temperature
    4. Add 25μL of IQELISA Detection Reagent to each well. Incubate 1 hour
    5. Add 15μL Primer solution 10μL of PCR master mix to each well
    6. Run real-time PCR
    限制
    仅限研究用
  • 储存条件
    4 °C,-20 °C,-80 °C
    储存方法
    May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.
    有效期
    6 months
  • 抗原 See all PAR1 (F2R) IQ-ELISA Kits
    PAR1 (F2R) (Coagulation Factor II (thrombin) Receptor (F2R))
    别名
    PAR1 (F2R 产品)
    别名
    CF2R IQ-ELISA Kit, HTR IQ-ELISA Kit, PAR-1 IQ-ELISA Kit, PAR1 IQ-ELISA Kit, TR IQ-ELISA Kit, Par1 IQ-ELISA Kit, TRGPC IQ-ELISA Kit, AI482343 IQ-ELISA Kit, Cf2r IQ-ELISA Kit, ThrR IQ-ELISA Kit, Par-1 IQ-ELISA Kit, f2r-a IQ-ELISA Kit, par1 IQ-ELISA Kit, coagulation factor II thrombin receptor IQ-ELISA Kit, coagulation factor II (thrombin) receptor IQ-ELISA Kit, coagulation factor 2 (thrombin) receptor L homeolog IQ-ELISA Kit, F2R IQ-ELISA Kit, F2r IQ-ELISA Kit, f2r.L IQ-ELISA Kit
    基因ID
    2149
    UniProt
    P25116
    途径
    Nuclear Receptor Transcription Pathway, Skeletal Muscle Fiber Development, Positive Regulation of Endopeptidase Activity, Protein targeting to Nucleus