电话:
400-7060-959
传真:
+86 10 56315212-8813
电子邮件:
orders@antibodies-online.cn

HMGB1 ELISA 试剂盒

HMGB1 适用: 人 Colorimetric Sandwich ELISA 62.5 pg/mL - 4000 pg/mL Plasma, Serum
产品编号 ABIN5564695
发货至: 中国
  • 抗原 See all HMGB1 ELISA试剂盒
    HMGB1 (High Mobility Group Box 1 (HMGB1))
    适用
    • 6
    • 3
    • 3
    • 3
    • 3
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    检测方法
    Colorimetric
    实验类型
    Sandwich ELISA
    检测范围
    62.5 pg/mL - 4000 pg/mL
    最低检测浓度
    62.5 pg/mL
    应用范围
    ELISA
    样品类型
    Plasma, Serum
    Analytical Method
    Quantitative
    特异性

    This assay has high sensitivity and excellent specificity for detection of Instant High Mobility Group Protein 1 (HMG1).
    No significant cross-reactivity or interference between Instant High Mobility Group Protein 1 (HMG1) and analogues was observed.

    灵敏度
    22.5 pg/mL
    组件
    • Pre-coated, ready to use 96-well strip plate, flat buttom
    • Plate sealer for 96 wells
    • Reference Standard
    • Standard Diluent
    • Detection Reagent A
    • Detection Reagent B
    • Assay Diluent A
    • Assay Diluent B
    • Reagent Diluent (if Detection Reagent is lyophilized)
    • TMB Substrate
    • Stop Solution
    • Wash Buffer (30 x concentrate)
    • Instruction manual
    试剂未包括
    • Microplate reader with 450 nm filter.
    • Precision single or multi-channel pipettes and disposable tips.
    • Eppendorf Tubes for diluting samples.
    • Deionized or distilled water.
    • Absorbent paper for blotting the microtiter plate.
    • Container for Wash Solution
    Featured
    Discover our best selling HMGB1 ELISA Kit
    Top Product
    Discover our top product HMGB1 ELISA Kit
  • 实验时间
    1.5 h
    板类型
    Pre-coated
    实验流程
    The test principle applied in this kit is enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Instant High Mobility Group Protein 1 (HMG1). Standards or samples and HRP-labeled detection antibody specific to Instant High Mobility Group Protein 1 (HMG1) (Detection Reagent A) are then added to the appropriate microtiter plate wells. Next, TMB substrate solution is added, only those wells that contain Instant High Mobility Group Protein 1 (HMG1), and HRP-labeled detection antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Instant High Mobility Group Protein 1 (HMG1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
    试剂准备
    1. Bring all kit components and samples to room temperature (18-25 °C) before use. If the kit will not be used up in one time, please only take out strips and reagents for present experiment, and leave the remaining strips and reagents in required condition.
    2. Standard - Reconstitute the Standard with 1.0 mL of Standard Diluent, keep for 10 minutes at room temperature, shake gently (not to foam). The concentration of the standard in the stock solution is 2,000pg/mL. Firstly dilute the stock solution to 1,000 pg/mL and the diluted standard serves as the highest standard (1,000 pg/mL). Then prepare 7 tubes containing 0.5 mL Standard Diluent and produce a double dilution series by transferring 500 µL each. Mix each tube thoroughly before the next transfer. Set up 7 points of diluted standard such as 1,000pg/mL, 500pg/mL, 250pg/mL, 125pg/mL, 62.5pg/mL, 31.2pg/mL, 15.6pg/mL, and the last microcentrifuge tube with Standard Diluent is the blank as 0pg/mL.
    3. Detection Reagent A and Detection Reagent B - If lyophilized reconstitute the Detection Reagent A with 150μL of Reagent Diluent, keep for 10 minutes at room temperature, shake gently (not to foam). Briefly spin or centrifuge the stockDetection A and Detection B before use. Dilute them to the working concentration 100-fold with Assay Diluent A and B, respectively.
    4. Wash Solution - Dilute 20 mL of Wash Solution concentrate (30x) with 580 mL of deionized or distilled water to prepare 600 mL of Wash Solution (1x).
    5. TMB substrate - Aspirate the needed dosage of the solution with sterilized tips and do not dump the residual solution into the vial again.

    Note:

    1. Making serial dilution in the wells directly is not permitted.
    2. Prepare standard within 15 minutes before assay. Please do not dissolve the reagents at 37 °C directly.
    3. Please carefully reconstitute Standards or working Detection Reagent A and B according to the instruction, and avoid foaming and mix gently until the crystals are completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10μL for once pipetting.
    4. The reconstituted Standards, Detection Reagent A and Detection Reagent B can be used only once.
    5. Prepare Substrate working Solution within 15 minutes before assay.
    6. If crystals have formed in the Wash Solution concentrate (30x), warm to room temperature and mix gently until the crystals are completely dissolved.
    7. Contaminated water or container for reagent preparation will influence the detection result.
    实验流程
    1. Prepare all reagents, samples and standards,
    2. Add 100μL standard or sample to each well. Incubate 2 hours at 37 °C,
    3. Aspirate and add 100μL prepared Detection Reagent A. Incubate 1 hour at 37 °C,
    4. Aspirate and wash 3 times,
    5. Add 100μL prepared Detection Reagent B. Incubate 30 minutes at 37 °C,
    6. Aspirate and wash 5 times,
    7. Add 90μL Substrate Solution. Incubate 10-20 minutes at 37 °C,
    8. Add 50μL Stop Solution. Read at 450nm immediately.
    实验精密度

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Instant High Mobility Group Protein 1 (HMG1) were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Instant High Mobility Group Protein 1 (HMG1) were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    限制
    仅限研究用
  • 注意事项
    The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
    注意事项
    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
    储存条件
    4 °C
    储存方法
    • For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
    • For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
      Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit.
    • For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.
    有效期
    6 months
  • 抗原 See all HMGB1 ELISA试剂盒
    HMGB1 (High Mobility Group Box 1 (HMGB1))
    别名
    High Mobility Group Protein 1 (HMG1) (HMGB1 产品)
    别名
    HMG1 ELISA Kit, HMG3 ELISA Kit, SBP-1 ELISA Kit, DEF ELISA Kit, HMG-1 ELISA Kit, Hmg1 ELISA Kit, amphoterin ELISA Kit, p30 ELISA Kit, hmgb1 ELISA Kit, ik:tdsubc_1a5 ELISA Kit, wu:fb23c02 ELISA Kit, xx:tdsubc_1a5 ELISA Kit, zgc:56110 ELISA Kit, zgc:77104 ELISA Kit, hmg-1 ELISA Kit, hmg3 ELISA Kit, sbp-1 ELISA Kit, hmg1 ELISA Kit, HMGB1 ELISA Kit, Ac2-008 ELISA Kit, high mobility group box 1 ELISA Kit, high-mobility group box 1 ELISA Kit, high mobility group box 1a ELISA Kit, high mobility group box 1 L homeolog ELISA Kit, high mobility group protein B1 ELISA Kit, HMGB1 ELISA Kit, Hmgb1 ELISA Kit, hmgb1 ELISA Kit, hmgb1a ELISA Kit, hmgb1.L ELISA Kit, LOC100359149 ELISA Kit
    UniProt
    P09429
    途径
    p53 Pathway, Regulation of Muscle Cell Differentiation, Skeletal Muscle Fiber Development, Positive Regulation of Endopeptidase Activity, Regulation of Carbohydrate Metabolic Process, Toll-Like Receptors Cascades, Smooth Muscle Cell Migration, Inflammasome
You are here:
客服