电话:
400-7060-959
传真:
+86 10 56315212-8813
电子邮件:
orders@antibodies-online.cn

CRP ELISA 试剂盒

CRP 适用: 人 Colorimetric Sandwich ELISA 0.625-40 ng/mL Cell Culture Supernatant, Plasma, Serum, Tissue Homogenate
产品编号 ABIN366539
发货至: 中国
  • 抗原 See all CRP ELISA试剂盒
    CRP (C-Reactive Protein (CRP))
    适用
    • 8
    • 8
    • 5
    • 5
    • 4
    • 3
    • 3
    • 2
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    检测方法
    Colorimetric
    实验类型
    Sandwich ELISA
    检测范围
    0.625-40 ng/mL
    最低检测浓度
    0.625 ng/mL
    应用范围
    ELISA
    原理
    For the quantitative determination of human high sensitivity C-reactive protein (hs-CRP) concentrations in serum, plasma, cell culture supernates, tissue homogenates.
    样品类型
    Serum, Plasma, Cell Culture Supernatant, Tissue Homogenate
    Analytical Method
    Quantitative
    特异性
    This assay has high sensitivity and excellent specificity for detection of human CRP.
    交叉反应 (详细)
    Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between the target antigen and all analogues for other species. Therefore, cross reaction may still exist.
    灵敏度
    0.156 ng/mL
    组件
    • Assay plate (12 × 8 coated Microwells)
    • Standard (freeze dried)
    • Biotin-antibody (100 × concentrate)
    • HRP-avidin (100 × concentrate)
    • Biotin-antibody Diluent
    • HRP-avidin Diluent
    • Sample Diluent
    • Wash Buffer (25 × concentrate)
    • TMB Substrate
    • Stop Solution
    • Adhesive Strip (for 96 wells)
    • Instruction manual
    试剂未包括
    • Microplate reader capable of measuring absorbance at 450nm, with the correction wavelength set at 540nm or 570nm.
    • An incubator which can provide stable incubation conditions up to 37°C ± 0.5°C.
    • Squirt bottle, manifold dispenser or automated microplate washer.
    • Absorbent paper for blotting the microtiter plate.
    • 100mL and 500mL graduated cylinders.
    • Deionized or distilled water.
    • Pipettes and pipette tips.
    • Test tubes for dilution.
    Featured
    Discover our best selling CRP ELISA Kit
    Top Product
    Discover our top product CRP ELISA Kit
  • 应用备注
    • The supplier is only responsible for the kit itself, but not for the samples consumed during the assay. The user should calculate the possible amount of the samples used in the whole test. Please reserve sufficient samples in advance.
    • Samples to be used within 5 days may be stored at 2-8°C, otherwise samples must be stored at -20°C (≤ 1 month) or -80°C (≤ 2 months) to avoid loss of bioactivity and contamination.
    • Grossly hemolyzed samples are not suitable for use in this assay.
    • If the samples are not indicated in the manual, a preliminary experiment to determine the validity of the kit is necessary.
    • Please predict the concentration before assaying. If values for these are not within the range of the standard curve, users must determine the optimal sample dilutions for their particular experiments.
    • Tissue or cell extraction samples prepared by chemical lysis buffer may cause unexpected ELISA results due to the impacts of certain chemicals.
    • Owing to the possibility of mismatching between antigens from another resource and antibodies used in this supplier's kits (e.g., antibody targets conformational epitope rather than linear epitope), some native or recombinant proteins from other manufacturers may not be recognized by this supplier's products.
    • Influenced by factors including cell viability, cell number and cell sampling time, samples from cell culture supernatant may not be recognized by the kit.
    • Fresh samples without long time storage are recommended for the test. Otherwise, protein degradation and denaturalization may occur in those samples and finally lead to wrong results.
    说明

    Detection wavelength: 450 nm

    Information on standard material:
    Depending on the antigen to be detected, standards can be either native or recombinant protein. The recombinant proteins are being expressed in CHO cells in most cases. Please inquire for more information. The formulation of auxiliary material in the standard is considered proprietary information, however it does not contain any poisonous substance. Proclin 300 (1:3000) is used as preservative.

    Information on reagents:
    In most cases the stop solution provided is 1 N H2SO4. The formulation of wash solution is proprietary information. None of the components contain (sodium) azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials. For the sandwich method kits, the sample diluent, antibody diluent, enzyme diluent and standard all contain BSA.

    Information on antibodies:
    The antibodies provided in different kits vary in regards to clonality and host. Some antibodies are affinity purified, some are Protein A

    样本量
    100 μL
    实验时间
    1 - 4.5 h
    板类型
    Pre-coated
    实验流程
    This assay employs the quantitative sandwich enzyme immunoassay technique. Antibody specific for CRP has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any CRP present is bound by the immobilized antibody. After removing any unbound substances, a Horseradish Peroxidase (HRP)-conjugated antibody specific for CRP is added to the wells. Following a wash to remove any unbound reagent, a substrate solution is added to the wells and color develops in proportion to the amount of CRP bound in the initial step. The color development is stopped and the intensity of the color is measured.
    样品收集
    • Serum: Use a serum separator tube (SST) and allow samples to clot for two hours at room temperature or overnight at 4 °C before centrifugation for 15 minutes at 1000 × g. Remove serum and assay immediately or aliquot and store samples at -20 °C or -80 °C. Avoid repeated freeze-thaw cycles.
    • Plasma: Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 × g at 2-8 °C within 30 minutes of collection. Assay immediately or aliquot and store samples at -20 °C or -80 °C. Avoid repeated freeze-thaw cycles.
    • Tissue Homogenates: Rinse 100 mg tissue with 1× PBS, homogenize in 1mL of 1× PBS and store overnight at -20 °C. After two freeze-thaw cycles to break the cell membranes, centrifuge the homogenates for 5 minutes at 5000 × g, 2-8 °C. Remove and assay the supernate immediately. Alternatively, aliquot and store samples at -20 °C or -80 °C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
    结果分析

    Average the duplicate readings for each standard and sample and subtract the average zero standard optical density.
    Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the target antigen concentration versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data.
    If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.

    实验精密度
    Intra-assay precision (precision within an assay): Three samples of known concentration were tested twenty times on one plate to assess precision.
    Inter-assay precision (precision between assays): Three samples of known concentration were tested in twenty assays to assess precision.
    • Intra-assay: CV% less than 8%
    • Inter-assay: CV% less than 10%
    限制
    仅限研究用
  • 注意事项
    The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face and clothing protection when using this material.
    注意事项
    • The kit should not be used beyond the expiration date on the kit label.
    • Do not mix or substitute reagents with those from other lots or sources.
    • If samples generate values higher than the highest standard, dilute the samples with Sample Diluent and repeat the assay.
    • Any variation in Sample Diluent, operator, pipetting technique, washing technique, incubation time/temperature and kit age can cause variation in binding.
    • This assay is designed to eliminate interference by soluble receptors, binding proteins and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
    储存条件
    4 °C/-20 °C
    储存方法
    For unopened kit: All the reagents should be kept according to the labels on vials.
    有效期
    6 months
  • Alavinezhad, Ghorani, Rajabi, Boskabady: "Zataria multiflora extract influenced asthmatic patients by improving respiratory symptoms, pulmonary function tests and lung inflammation." in: Journal of ethnopharmacology, Vol. 285, pp. 114888, (2022) (PubMed).

    Chen, Cheng, Shao, Shentu, Fu: "Macrophage migration inhibitory factor as a serum prognostic marker in patients with aneurysmal subarachnoid hemorrhage." in: Clinica chimica acta; international journal of clinical chemistry, Vol. 473, pp. 60-64, (2018) (PubMed).

    Hu, Wang, Wang, Lai, Chen, Duan, Zhao, Huang et al.: "Combined moderate and high intensity exercise with dietary restriction improves cardiac autonomic function associated with a reduction in central and systemic arterial stiffness in obese adults: a ..." in: PeerJ, Vol. 5, pp. e3900, (2018) (PubMed).

    Jiang, Tang, Zhang, Chao, Hong: "Association of serum C1q tumour necrosis factor-related protein 9 with the severity of lower extremity peripheral arterial disease in type 2 diabetes patients." in: Diabetes & vascular disease research, Vol. 15, Issue 3, pp. 270-273, (2018) (PubMed).

    Ghazali, Romli, Mohamed: "Effects of honey supplementation on inflammatory markers among chronic smokers: a randomized controlled trial." in: BMC complementary and alternative medicine, Vol. 17, Issue 1, pp. 175, (2017) (PubMed).

    Huang, Wang, Xu, Wang, Yin, Lai, Liao, Hou, Hu: "Exercise training with dietary restriction enhances circulating irisin level associated with increasing endothelial progenitor cell number in obese adults: an intervention study." in: PeerJ, Vol. 5, pp. e3669, (2017) (PubMed).

    Tao, Zhou, Xu, Hao, Huang, Mou, Jiang, Tao, Zhu: "Inverse Correlation between Vitamin D and C-Reactive Protein in Newborns." in: Nutrients, Vol. 7, Issue 11, pp. 9218-28, (2016) (PubMed).

    Moura Neto, Parisi, Alegre, Pavin, Tambascia, Zantut-Wittmann: "Relation of thyroid hormone abnormalities with subclinical inflammatory activity in patients with type 1 and type 2 diabetes mellitus." in: Endocrine, (2015) (PubMed).

    Zhu, Liu, Zhang, Chu, Wu, Li, Ge, Dong, Zhu: "High levels of vitamin D in relation to reduced risk of schizophrenia with elevated C-reactive protein." in: Psychiatry research, Vol. 228, Issue 3, pp. 565-70, (2015) (PubMed).

    Fan, Wang, Meng, Li, Chang, Nian, Liang: "Panax notoginseng saponins mitigate ovariectomy-induced bone loss and inhibit marrow adiposity in rats." in: Menopause (New York, N.Y.), (2015) (PubMed).

    Madondo, Tuyaerts, Turnbull, Vanderstraeten, Kohrt, Narasimhan, Amant, Quinn, Plebanski: "Variability in CRP, regulatory T cells and effector T cells over time in gynaecological cancer patients: a study of potential oscillatory behaviour and correlations." in: Journal of translational medicine, Vol. 12, pp. 179, (2014) (PubMed).

    Kornej, Reinhardt, Kosiuk, Arya, Hindricks, Adams, Husser, Bollmann: "Response of circulating heat shock protein 70 and anti-heat shock protein 70 antibodies to catheter ablation of atrial fibrillation." in: Journal of translational medicine, Vol. 11, pp. 49, (2013) (PubMed).

    Yokobayashi, Sugaya, Miyagaki, Kai, Suga, Yamada, Minatani, Watanabe, Kikuchi, Tamaki, Sato: "Analysis of serum chemokine levels in patients with HIV-associated eosinophilic folliculitis." in: Journal of the European Academy of Dermatology and Venereology : JEADV, Vol. 27, Issue 2, pp. e212-6, (2013) (PubMed).

    Kornej, Reinhardt, Kosiuk, Arya, Hindricks, Adams, Husser, Bollmann: "Response of high-sensitive C-reactive protein to catheter ablation of atrial fibrillation and its relation with rhythm outcome." in: PLoS ONE, Vol. 7, Issue 8, pp. e44165, (2012) (PubMed).

    Jiang, Sun, Tang, Xu, Jiao: "Hepcidin expression and iron parameters change in Type 2 diabetic patients." in: Diabetes research and clinical practice, Vol. 93, Issue 1, pp. 43-8, (2011) (PubMed).

    Inoue, Sugiyama, Reid, Ito, Miyauchi, Mukai, Sagara, Miyamoto, Satoh, Kohno, Kurata, Ota, Mantovani, Hamakubo, Daida, Kodama: "Establishment of a high sensitivity plasma assay for human pentraxin3 as a marker for unstable angina pectoris." in: Arteriosclerosis, thrombosis, and vascular biology, Vol. 27, Issue 1, pp. 161-7, (2007) (PubMed).

  • 抗原 See all CRP ELISA试剂盒
    CRP (C-Reactive Protein (CRP))
    别名
    high sensitivity C-Reactive Protein (hs-CRP) (CRP 产品)
    别名
    PTX1 ELISA Kit, crp ELISA Kit, AI255847 ELISA Kit, Aa1249 ELISA Kit, Ab1-341 ELISA Kit, Ab2-196 ELISA Kit, Ac1-114 ELISA Kit, Ac1262 ELISA Kit, Ac2-069 ELISA Kit, Ba2-693 ELISA Kit, APCS ELISA Kit, 0610010I23Rik ELISA Kit, AW743261 ELISA Kit, C77570 ELISA Kit, CRP2 ELISA Kit, CRP4 ELISA Kit, Crp ELISA Kit, ESP1 ELISA Kit, Hlp ELISA Kit, CRP5.1 ELISA Kit, zgc:152809 ELISA Kit, C-reactive protein ELISA Kit, C-reactive protein, pentraxin-related ELISA Kit, c-reactive protein, pentraxin-related ELISA Kit, cysteine rich protein 2 ELISA Kit, CRP ELISA Kit, crp ELISA Kit, Crp ELISA Kit, Crip2 ELISA Kit, LOC776376 ELISA Kit
    途径
    Carbohydrate Homeostasis
You are here:
客服